EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Piezoelectric row-column sensing system on table tennis rackets for hit and rotation measurement

Chao Zhang, Zile Fan iD, Yafeng Kang iD

PLOS One · 2025

DOI: 10.1371/journal.pone.0333735 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, 2025. Verfasst von Chao Zhang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Shanghai University of Finance and Economics Zhejiang College, Jinhua, Zhejiang, China. Hauptthemen laut MEDLINE: Tennis, Wearable Electronic Devices, Sports Equipment. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable sensing systems are often constrained by the number of available signal channels: expanding the sensor number typically improves human motion monitoring but drives up hardware complexity. In this paper, a row-column sensing method is proposed to address this limitation in the context of table tennis impact monitoring. The hit sensing position on the racket is decomposed into orthogonal row and column coordinates, with only one single striped piezoelectric PVDF (Polyvinylidene fluoride) flexible sensor placed on each axis. By combining the signals on each row and column, the hitting position is analytically obtained. In a 5 × 5 layout this architecture reduces required signal pathways from 25 to 10 (five rows plus five columns) while delivering same spatial accuracy. Additionally, the denser set of impact locations also enables detection of ball spin. In‑plane and out‑of‑plane rotations produce distinct stress distributions across the racket surface, which the array captures through differential row and column signal patterns. This approach can be extended to other wearable or sports devices that need higher spatial resolution without proportional increases in channel count, and it shows clear potential for advancing table tennis training, officiating, and performance analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TennisWearable Electronic DevicesSports EquipmentHumansRotationPolyvinylsEquipment DesignFluorocarbon Polymers

Substanzen

polyvinylidene fluoridePolyvinylsFluorocarbon Polymers

Autor:innen und Institutionen

  • Shanghai University of Finance and Economics Zhejiang College, Jinhua, Zhejiang, China.
  • School of Marxism Studies, Yiwu Industrial and Commercial College, Yiwu, Zhejiang, China.
  • Xingzhi College, Zhejiang Normal University, Jinhua, Zhejiang, China.

ORCID-Profile: Zile Fan, Yafeng Kang

Zitieren

APA

Zhang, C., Fan, Z., & Kang, Y. (2025). Piezoelectric row-column sensing system on table tennis rackets for hit and rotation measurement. PLOS One. https://doi.org/10.1371/journal.pone.0333735

Vancouver

Zhang C, Fan Z, Kang Y. Piezoelectric row-column sensing system on table tennis rackets for hit and rotation measurement. PLOS One. 2025. doi:10.1371/journal.pone.0333735

BibTeX
@article{Zhang2025,
  author = {Zhang, Chao and Fan, Zile and Kang, Yafeng},
  title = {Piezoelectric row-column sensing system on table tennis rackets for hit and rotation measurement},
  journal = {PLOS One},
  year = {2025},
  doi = {10.1371/journal.pone.0333735}
}
Kostenlos starten →