EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accurate measurement of simulated slow and altered walking activity: Apple Watch best in class wearable devices

Grant Rowe, David Weight, Alethea Rea iD, Jenny Conlon, Fiona M Wood, Dale W Edgar iD

PLOS One · 2025

DOI: 10.1371/journal.pone.0333504 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, 2025. Verfasst von Grant Rowe und 5 weiteren Autor:innen. Beteiligte Einrichtung: Discipline of Psychology, College of Science, Health, Engineering and Education, Murdoch University, Perth, Western Australia, Australia. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Walking, Monitoring, Ambulatory. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Wearable activity devices, widely used to monitor physical activity in non-injured populations, have shown potential in encouraging early ambulation and enhanced recovery in hospitalised patients. This study evaluated the accuracy of wearable devices in tracking step counts under simulated hospital conditions, seeking the optimal body location placement for individuals with altered gait.

Methods

This method comparison study involved healthy adults walking on a treadmill while performing slow and shuffling walking patterns. Twelve wearable devices were placed on the arm, waist, and leg, and their recorded step counts were compared to manual counts from filmed sessions, following Consumer Technology Association guidelines.

Results

The Apple Watch, particularly when worn on the waist, demonstrated the highest reliability and adaptability across walking patterns. Leg placement, which accounted for 10 of the top 20 device-position combinations, suggested that larger movement amplitudes improve step count accuracy, particularly during slow or altered gaits.

Conclusion

This study confirmed the Apple Watch to be the most accurate wearable step count device. The study provides new understanding as to the precision of commercially available devices and their placement, when aiming to improve and, or conduct research about, patient physical activity outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesWalkingMonitoring, AmbulatoryHumansMaleAdultFemaleYoung AdultGaitReproducibility of Results

Autor:innen und Institutionen

  • Discipline of Psychology, College of Science, Health, Engineering and Education, Murdoch University, Perth, Western Australia, Australia.
  • School of Mathematics, Statistics, Chemistry and Physics, Murdoch University, Murdoch, Western Australia, Australia.
  • Fiona Wood Foundation, Fiona Stanley Hospital, Murdoch, Western Australia, Australia.
  • Faculty of Medicine, Nursing, Midwifery and Health Sciences, School of Health Sciences, The University of Notre Dame Australia, Fremantle, Western Australia, Australia.
  • State Adult Burn Unit, Level 4, Fiona Stanley Hospital, Murdoch, Western Australia, Australia.
  • Burn Injury Research Unit, University of Western Australia, Crawley, Western Australia, Australia.

ORCID-Profile: Alethea Rea, Dale W Edgar

Zitieren

APA

Rowe, G., Weight, D., Rea, A., Conlon, J., Wood, F. M., & Edgar, D. W. (2025). Accurate measurement of simulated slow and altered walking activity: Apple Watch best in class wearable devices. PLOS One. https://doi.org/10.1371/journal.pone.0333504

Vancouver

Rowe G, Weight D, Rea A, Conlon J, Wood FM, Edgar DW. Accurate measurement of simulated slow and altered walking activity: Apple Watch best in class wearable devices. PLOS One. 2025. doi:10.1371/journal.pone.0333504

BibTeX
@article{Rowe2025,
  author = {Rowe, Grant and Weight, David and Rea, Alethea and Conlon, Jenny and Wood, Fiona M and Edgar, Dale W},
  title = {Accurate measurement of simulated slow and altered walking activity: Apple Watch best in class wearable devices},
  journal = {PLOS One},
  year = {2025},
  doi = {10.1371/journal.pone.0333504}
}
Kostenlos starten →