A deep learning AI model for determining the relationship between X-Ray detectors and patient positioning in chest radiography
PLOS One · 2025
DOI: 10.1371/journal.pone.0333209 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, 2025. Verfasst von Bo Jiang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, The Second Xiangya Hospital of Central South University, Changsha, Hunan, China. Hauptthemen laut MEDLINE: Deep Learning, Patient Positioning, Radiography, Thoracic. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Natural Science Foundation of Hunan Province, Clinical Medical Technology Innovation and Guidance Project In Hunan Province.
Abstract (Originalsprache)
Purpose
The objective of this study was to create an artificial intelligence (AI) system capable of automatically detecting the positional relationship between an X-ray detector and the patient during anteroposterior chest radiography.
Methods
In this study, a total of 22299 images depicting the positional states of X-ray detectors relative to patients were used to develop an AI system for the automatic determination of X-ray detector status. The images were captured from Routine clinical chest X-ray radiography practice settings, without exposing any patient privacy, adhering to the Declaration of Helsinki. The PyTorch library was utilized for customizing a Convolutional Neural Network (CNN) model for the training of the chest radiography positional determination model.
Results
The average accuracy of Model A on the validation set was 0.9668, with an average loss function value of 0.1078. In contrast, Model B achieved an average accuracy of 0.9776, also with an average loss function value of 0.0970. In the test set results, Model A -fold 4 demonstrated a true negative rate (TNR) of 0.9925, negative predictive value (NPV) of 0.9925, precision of 0.9699, recall of 0.9700, accuracy of 0.9700, and an F1 score of 0.9699. Model B -fold 1exhibited a TNR of 0.9946, NPV of 0.9946, precision of 0.9787, recall of 0.9784, accuracy of 0.9784, and an F1 score of 0.9784. McNemar’s test indicated statistical difference between the two models.
Conclusion
The AI model utilizing a customized CNN architecture has demonstrated its potential to automatically detect the positional relationship between the patient and the X-ray detector during chest radiography procedures. This model can potentially alleviate the workload of radiologic technologists in producing chest radiographs and enhance the accuracy of the imaging process.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Radiology, The Second Xiangya Hospital of Central South University, Changsha, Hunan, China.
ORCID-Profile: Weijun Situ
Förderung
- The Natural Science Foundation of Hunan Province
- Clinical Medical Technology Innovation and Guidance Project In Hunan Province
Zitieren
APA
Jiang, B., Hu, J., Chen, X., Wu, X., Deng, K., Yang, H., Situ, W., & Jiang, S. (2025). A deep learning AI model for determining the relationship between X-Ray detectors and patient positioning in chest radiography. PLOS One. https://doi.org/10.1371/journal.pone.0333209
Vancouver
Jiang B, Hu J, Chen X, Wu X, Deng K, Yang H, et al. A deep learning AI model for determining the relationship between X-Ray detectors and patient positioning in chest radiography. PLOS One. 2025. doi:10.1371/journal.pone.0333209
BibTeX
@article{Jiang2025,
author = {Jiang, Bo and Hu, Junjiao and Chen, Xiaofan and Wu, Xiong and Deng, Kai and Yang, Haitao and Situ, Weijun and Jiang, Shan},
title = {A deep learning AI model for determining the relationship between X-Ray detectors and patient positioning in chest radiography},
journal = {PLOS One},
year = {2025},
doi = {10.1371/journal.pone.0333209}
}
EUVIMED