Fachartikel in der Zeitschrift PLOS One, online erschienen am 29.09.2025. Verfasst von Bongyeon Sohn und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Thoracic and Cardiovascular Surgery, Bucheon Sejong Hospital, Bucheon, Gyeonggi-do, Republic of Korea. Hauptthemen laut MEDLINE: Cardioplegic Solutions, Heart Arrest, Induced, Aortic Valve, Heart Valve Prosthesis Implantation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to evaluate the safety and efficacy of a modified, bloodless Del Nido (DN) cardioplegia solution in patients undergoing isolated aortic valve replacement (AVR). A total of 370 patients who underwent isolated AVR between 2015 and 2022 were retrospectively analyzed. Patients were categorized into two groups based on the cardioplegia solution used: the bloodless DN group (N = 180) and the histidine-tryptophan-ketoglutarate (HTK) group (N = 190). To reduce selection bias and adjust for baseline differences, inverse probability of treatment weighting analysis was performed. There was no significant difference in in-hospital mortality between the two groups (HTK vs. DN: 1.2% vs. 0.9%, P = 0.554). However, the rate of spontaneous sinus rhythm restoration without the need for defibrillation following aortic cross-clamp release was significantly higher in the DN group (40.0% vs. 75.2%, P < 0.001). Additionally, the initial postoperative lactate level (3.0 ± 2.6 mmol/L vs. 2.2 ± 1.4 mmol/L, P = 0.002), and the incidence of low cardiac output syndrome (9.4% vs. 1.7%, P < 0.001) were significantly lower in the DN group compared to the HTK group. Other postoperative morbidities did not differ significantly between the groups. The modified bloodless Del Nido cardioplegia demonstrated favorable myocardial protection and early clinical outcomes compared to HTK solution in patients undergoing isolated AVR. These findings suggest that the bloodless Del Nido technique may be a viable alternative, although further validation in larger, prospective studies is warranted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardioplegic SolutionsHeart Arrest, InducedAortic ValveHeart Valve Prosthesis ImplantationHumansMaleFemaleAgedRetrospective StudiesMiddle AgedPotassium ChlorideTreatment OutcomeMannitolHospital MortalityGlucoseProcaineSodium BicarbonateLidocaineMagnesium SulfateElectrolytesSolutions

Substanzen

Cardioplegic SolutionsDel Nido cardioplegia solutionPotassium ChlorideMannitolGlucoseProcaineSodium BicarbonateLidocaineMagnesium SulfateElectrolytes

Autor:innen und Institutionen

  • Department of Thoracic and Cardiovascular Surgery, Bucheon Sejong Hospital, Bucheon, Gyeonggi-do, Republic of Korea.
  • Department of Thoracic and Cardiovascular Surgery, Asan Medical Center, Seoul, Republic of Korea.

ORCID-Profile: Bongyeon Sohn, Heemoon Lee

Zitieren

APA

Sohn, B., Yoo, J. S., Kim, D. J., & Lee, H. (2025). The efficacy of modified bloodless del Nido cardioplegia in isolated aortic valve replacement. PLOS One, 20(9), e0333083. https://doi.org/10.1371/journal.pone.0333083

Vancouver

Sohn B, Yoo JS, Kim DJ, Lee H. The efficacy of modified bloodless del Nido cardioplegia in isolated aortic valve replacement. PLOS One. 2025;20(9):e0333083. doi:10.1371/journal.pone.0333083

BibTeX
@article{Sohn2025,
  author = {Sohn, Bongyeon and Yoo, Jae Suk and Kim, Dong Jin and Lee, Heemoon},
  title = {The efficacy of modified bloodless del Nido cardioplegia in isolated aortic valve replacement},
  journal = {PLOS One},
  year = {2025},
  volume = {20},
  number = {9},
  pages = {e0333083},
  doi = {10.1371/journal.pone.0333083}
}
Kostenlos starten →