Comparison of visual function analysis of people with low vision using three different models of augmented reality devices
PLOS One · 08.10.2025 · 20 (10) · e0332085
DOI: 10.1371/journal.pone.0332085 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift PLOS One, online erschienen am 08.10.2025. Verfasst von Sarika Gopalakrishnan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Postdoctoral Researcher, Envision Research Institute, United States of America. Hauptthemen laut MEDLINE: Visual Acuity, Vision, Low, Augmented Reality. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
We compared visual function in individuals with low vision (>20/60) using three different models of augmented reality (AR) devices: Ziru, IrisVision, and NuEyes-Pro3. The distance visual acuity (VA) was measured in high luminance high contrast (HLHC), high luminance low contrast (HLLC), low luminance high contrast (LLHC), and low luminance low contrast (LLLC) settings. The other tests were near VA, distance and near contrast sensitivity (CS), color vision, depth perception and indoor navigation. The change in visual function without and with AR devices was analyzed. Out of 27 participants, 17 were female. The mean age was 66.7 ± 18.2 years. The median baseline VA was 0.66 (0.79) logMAR in HLHC, 0.87 (0.54) logMAR in HLLC, 0.84 (0.67) logMAR in LLHC and 1.04 (0.34) logMAR in LLLC. The median baseline near VA was 0.55(0.4) logMAR, distance and near CS was 1.10(0.26) logCS, and 1.20(0.30) logCS respectively. Distance and near vision showed significant differences with both Ziru and IrisVision (p < 0.01), but not with NuEyes. There was a significant change in CS using Ziru and IrisVision for both distance and near (p < 0.05) but both reduced significantly with NuEyes (p < 0.01). During the objective identification task on the indoor environment using AR devices, head-level objects were missed more compared to waist or floor-level objects across all three models. Majority of the visual functions improved with Ziru and IrisVision, with limited improvement in certain lighting condition of distance visual acuity with NuEyes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Postdoctoral Researcher, Envision Research Institute, United States of America.
- Assistant Professor, SUNY, Department of Biological and Vision Sciences, SUNY College of Optometry, New York, United States of America.
- Biotechnical R&D Consultant, United States of America.
- Medical Director, Envision Vision Rehabilitation Center, Wichita, Kansas, United States of America.
- Smith-Kettlewell Eye Research Institute, San Francisco, California, United States of America.
ORCID-Profile: Sarika Gopalakrishnan
Zitieren
APA
Gopalakrishnan, S., Kartha, A., Schuchard, R., & Fletcher, D. (2025). Comparison of visual function analysis of people with low vision using three different models of augmented reality devices. PLOS One, 20(10), e0332085. https://doi.org/10.1371/journal.pone.0332085
Vancouver
Gopalakrishnan S, Kartha A, Schuchard R, Fletcher D. Comparison of visual function analysis of people with low vision using three different models of augmented reality devices. PLOS One. 2025;20(10):e0332085. doi:10.1371/journal.pone.0332085
BibTeX
@article{Gopalakrishnan2025,
author = {Gopalakrishnan, Sarika and Kartha, Arathy and Schuchard, Ronald and Fletcher, Donald},
title = {Comparison of visual function analysis of people with low vision using three different models of augmented reality devices},
journal = {PLOS One},
year = {2025},
volume = {20},
number = {10},
pages = {e0332085},
doi = {10.1371/journal.pone.0332085}
}