Evaluation of collector spacing, positioning, and nozzle selection methods on water distribution uniformity in center pivots
PLOS One · 12.09.2025 · 20 (9) · e0331122
DOI: 10.1371/journal.pone.0331122 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, online erschienen am 12.09.2025. Verfasst von Lucas Maltoni Andrade und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Agricultural Engineering, Center of Agricultural Sciences, Federal University of Viçosa, Viçosa, Minas Gerais, Brazil. Hauptthemen laut MEDLINE: Agricultural Irrigation, Water, Water Supply. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordination for the Improvement of Higher Education Personnel - Brazil, National Council for Scientific and Technological Development - Brazil.
Abstract (Originalsprache)
Proper design and periodic evaluation of center pivot irrigation systems are essential for ensuring uniform water distribution and improving water use efficiency in irrigated agriculture. This study assessed the impact of collector spacing and sampling methods, including a single-level collector line and combinations of multiple lines at different irrigated locations, on water distribution uniformity. Additionally, strategies for selecting emitter nozzles were analyzed. Uniformity assessments were conducted on two center pivots (P180 and P360) using collectors spaced at 1 m, with simulated spacings of up to 12 m by omitting intermediate readings. Collector lines were placed perpendicular to the pivot’s movement at 50% regulation and were evaluated three times. Data were analyzed individually for each line position and in groups, following layout recommendations from the literature. The mean water depth (L M ), weighted mean depth (L W ), and modified Christiansen’s uniformity coefficient (CUC HH ) were used as evaluation metrics. Flow rate measurements were performed, with three repetitions per nozzle number. Nozzle selection considered the required flow rate and nozzle diameter for both constant and doubled spacing between emitters in the first two spans. Measured flow rates resulted in higher simulated water depths and lower CUC HH values compared to simulated reference flow rates. However, the average field CUC HH exceeded 90% for both pivots, being classified as excellent. Evaluation methods combining different collector line positions showed no significant differences between means, nor did the combined effect of collector spacing and single-line positioning. No significant differences were found between collector spacings alone. However, collector line positioning influenced results, with P180 showing differences in L W and P360 in L M , L W , and CUC HH . Estimated evaporation and wind drift losses were 14.21% for P360 and 13.49% for P180. The evaluated nozzle selection combinations showed a theoretical CUC HH higher than the simulated values based on the original nozzle listing for both pivots.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Agricultural Engineering, Center of Agricultural Sciences, Federal University of Viçosa, Viçosa, Minas Gerais, Brazil.
- Institute of Agricultural Sciences, Federal University of Viçosa, Rio Paranaíba Campus, Minas Gerais, Brazil.
- Department of Statistics, Center of Exact Sciences, Federal University of Viçosa, Viçosa, Minas Gerais, Brazil.
- Department of Agronomy, Federal University of Mato Grosso do Sul, Chapadão do Sul Campus, Mato Grosso do Sul, Brazil.
ORCID-Profile: Lucas Maltoni Andrade, Fernando França da Cunha
Förderung
- Coordination for the Improvement of Higher Education Personnel - Brazil
- National Council for Scientific and Technological Development - Brazil
Zitieren
APA
Andrade, L. M., Oliveira, R. A., Cunha, F. F. D., Drumond, L. C. D., Cecon, P. R., Oliveira, J. T., & Aleman, C. C. (2025). Evaluation of collector spacing, positioning, and nozzle selection methods on water distribution uniformity in center pivots. PLOS One, 20(9), e0331122. https://doi.org/10.1371/journal.pone.0331122
Vancouver
Andrade LM, Oliveira RA, Cunha FFD, Drumond LCD, Cecon PR, Oliveira JT, et al. Evaluation of collector spacing, positioning, and nozzle selection methods on water distribution uniformity in center pivots. PLOS One. 2025;20(9):e0331122. doi:10.1371/journal.pone.0331122
BibTeX
@article{Andrade2025,
author = {Andrade, Lucas Maltoni and Oliveira, Rubens Alves de and Cunha, Fernando França da and Drumond, Luis César Dias and Cecon, Paulo Roberto and Oliveira, Job Teixeira de and Aleman, Catariny Cabral},
title = {Evaluation of collector spacing, positioning, and nozzle selection methods on water distribution uniformity in center pivots},
journal = {PLOS One},
year = {2025},
volume = {20},
number = {9},
pages = {e0331122},
doi = {10.1371/journal.pone.0331122}
}
EUVIMED