ProSPective evaluation of the dIagnostic accuracy of siNe spiN non-contrast flatdEtectoR CT (FDCT) for the detection of intracranial hemorrhage in stroke patients - Protocol of a non-inferiority comparison to multi detector CT
PLOS One · 2025
DOI: 10.1371/journal.pone.0330608 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift PLOS One, 2025. Verfasst von Marios Psychogios und 23 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Neuroradiology, University Hospital Basel, Basel, Switzerland. Hauptthemen laut MEDLINE: Intracranial Hemorrhages, Stroke, Multidetector Computed Tomography, Tomography, X-Ray Computed. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Siemens Healthineers.
Themen: Schlaganfall
Abstract (Originalsprache)
Rationale
Whether syngo DynaCT Sine Spin non-contrast flat detector CT (FDCT) imaging is sufficient to rule out intracranial hemorrhage in suspected acute stroke patients is unknown.
Aim
To determine if syngo DynaCT Sine Spin non-contrast FDCT imaging is non-inferior to conventional multidetector CT (MDCT) imaging for the detection and exclusion of intracranial hemorrhages in suspected acute stroke patients. Sample size To enroll 252 participants in three buckets (126 ischemic stroke patients, 126 hemorrhagic stroke patients (including 14 patients with an isolated infratentorial hemorrhage). Methods and design A multicenter, international, prospective, cross-sectional, endpoint assessor blinded, non-inferiority trial. Outcomes The primary outcome is the occurrence of an intracranial hemorrhage (yes versus no). This will be used to calculate the sensitivity and specificity of FDCT imaging for the detection of intracranial hemorrhages. All FDCT images will be rated by six independent raters in a blinded imaging core-lab. The rating of the MDCT images will be deemed as ground-truth. FDCT imaging will be deemed non-inferior if the lower bound of the 95%-Confidence Interval of the sensitivity and specificity is above 95%.
Discussion
This trial will inform physicians whether syngo DynaCT Sine Spin non-contrast FDCT imaging can reliably exclude intracranial hemorrhages in patients with suspected acute stroke.
Trial registration
ClinicalTrials.gov NCT05458908
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Neuroradiology, University Hospital Basel, Basel, Switzerland.
- Department of Neurosurgery, Semmes Murphey Clinic and University of Tennessee Health Sciences Center, Memphis, Tennessee, United States of America.
- Service de Neuroradiologie, CHRU Tours, Tours, France.
- Department of Cerebrovascular Surgery, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania, United States of America.
- Department of Neurosurgery, Endeavor Health, Chicago, Illinois, United States of America.
- RIA Neurovascular, Englewood, Colorado, United States of America.
ORCID-Profile: Alex Brehm, Grzegorz M Karwacki, David S Liebeskind
Förderung
- Siemens Healthineers
Zitieren
APA
Psychogios, M., Brehm, A., Goyal, N., Boulouis, G., Burkhardt, J. K., Chowdhry, S. A., Frei, D., Gralla, J., Kaesmacher, J., Kellogg, R. T., Kellner, C. P., Lopes, D. K., Raz, E., Strbian, D., Mannismäki, L., Tomasello, A., Tsogkas, I., von Hessling, A., Karwacki, G. M., …, & SPINNERS investigators (2025). ProSPective evaluation of the dIagnostic accuracy of siNe spiN non-contrast flatdEtectoR CT (FDCT) for the detection of intracranial hemorrhage in stroke patients - Protocol of a non-inferiority comparison to multi detector CT. PLOS One. https://doi.org/10.1371/journal.pone.0330608
Vancouver
Psychogios M, Brehm A, Goyal N, Boulouis G, Burkhardt JK, Chowdhry SA, et al. ProSPective evaluation of the dIagnostic accuracy of siNe spiN non-contrast flatdEtectoR CT (FDCT) for the detection of intracranial hemorrhage in stroke patients - Protocol of a non-inferiority comparison to multi detector CT. PLOS One. 2025. doi:10.1371/journal.pone.0330608
BibTeX
@article{Psychogios2025,
author = {Psychogios, Marios and Brehm, Alex and Goyal, Nitin and Boulouis, Grégoire and Burkhardt, Jan-Karl and Chowdhry, Shakeel A and Frei, Donald and Gralla, Jan and Kaesmacher, Johannes and Kellogg, Ryan T and Kellner, Christopher P and Lopes, Demetrius K and Raz, Eytan and Strbian, Daniel and Mannismäki, Laura and Tomasello, Alejandro and Tsogkas, Ioannis and von Hessling, Alexander and Karwacki, Grzegorz M and Guzman, Raphael and Rommers, Nikki and Liebeskind, David S and Arthur, Adam S and SPINNERS investigators, SPINNERS investigators},
title = {ProSPective evaluation of the dIagnostic accuracy of siNe spiN non-contrast flatdEtectoR CT (FDCT) for the detection of intracranial hemorrhage in stroke patients - Protocol of a non-inferiority comparison to multi detector CT},
journal = {PLOS One},
year = {2025},
doi = {10.1371/journal.pone.0330608}
}