EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Methodological establishment and diagnostic value of a multiplex fluorescent PCR assay for the detection of three fastidious respiratory pathogens

Jingchao Shi, Yijun Zhu iD, Shuyun Chen, Xiaoyun Shan, Lihong Bo, Kai Shen, Keqiang Chen

PLOS One · 2025

DOI: 10.1371/journal.pone.0328651 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, 2025. Verfasst von Jingchao Shi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Laboratory, Affiliated Jinhua Hospital, Zhejiang University School of Medicine (Jinhua Municipal Central Hospital), Jinhua, Zh…. Hauptthemen laut MEDLINE: Multiplex Polymerase Chain Reaction, Haemophilus influenzae, Moraxella catarrhalis, Streptococcus pneumoniae. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science Technology Department of Zhejiang province, Jinhua Science and Technology Bureau.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Streptococcus pneumoniae , Haemophilus influenzae , and Moraxella catarrhalis are common fastidious bacteria responsible for respiratory tract infections, particularly in children and immunocompromised individuals. Due to their demanding growth requirements, traditional culture methods often yield low sensitivity and delayed results, posing challenges for early and accurate diagnosis.

Objective

To establish a TaqMan probe-based multiplex fluorescent PCR method for the simultaneous rapid detection and identification of three important respiratory fastidious pathogens: Streptococcus pneumoniae , Haemophilus influenzae , and Moraxella catarrhalis .

Methods

By designing and optimizing TaqMan probes and primers targeting Streptococcus pneumoniae , Haemophilus influenzae , and Moraxella catarrhalis , the sensitivity, specificity, and reproducibility of the TaqMan probe-based multiplex fluorescent PCR assay were examined. A total of 173 clinical samples which are sputum and alveolar lavage fluid were tested simultaneously using traditional culture methods and multiplex fluorescent PCR assays, and the results were compared for consistency. For samples with inconsistent detection results, targeted high-throughput sequencing (tNGS) was used for confirmation.

Results

The limit of detection of the TaqMan probe-based multiplex fluorescent PCR method was 100 Copies/ml for Streptococcus pneumoniae , 20 Copies/ml for Haemophilus influenzae , and 50 Copies/ml for Moraxella catarrhalis . The detection rate of the multiplex fluorescent PCR method was in high concordance with traditional culture methods and tNGS in the 173 clinical samples (Kappa = 0.819). The multiplex fluorescent PCR method demonstrated high sensitivity and specificity, detecting more cases of mixed infections.

Conclusion

The multiplex fluorescent PCR method established in this study provides a powerful tool for rapid and accurate clinical detection of fastidious respiratory pathogens, with significant clinical application value and promotion prospects. This method offers substantial advantages over traditional culture methods in terms of detection speed and sensitivity, particularly in detecting mixed infections, and has significant potential for clinical application and widespread adoption.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Multiplex Polymerase Chain ReactionHaemophilus influenzaeMoraxella catarrhalisStreptococcus pneumoniaeRespiratory Tract InfectionsHumansSensitivity and SpecificityReproducibility of ResultsSputum

Autor:innen und Institutionen

  • Department of Clinical Laboratory, Affiliated Jinhua Hospital, Zhejiang University School of Medicine (Jinhua Municipal Central Hospital), Jinhua, Zhejiang Province, China.
  • Hangzhou Dian Medical Center, Hangzhou, Zhejiang Province, China.
  • Key Laboratory of Digital Technology in Medical Diagnostics of Zhejiang Province, Hangzhou, Zhejiang Province, China.

ORCID-Profile: Yijun Zhu

Förderung

  • Science Technology Department of Zhejiang province
  • Jinhua Science and Technology Bureau

Zitieren

APA

Shi, J., Zhu, Y., Chen, S., Shan, X., Bo, L., Shen, K., & Chen, K. (2025). Methodological establishment and diagnostic value of a multiplex fluorescent PCR assay for the detection of three fastidious respiratory pathogens. PLOS One. https://doi.org/10.1371/journal.pone.0328651

Vancouver

Shi J, Zhu Y, Chen S, Shan X, Bo L, Shen K, et al. Methodological establishment and diagnostic value of a multiplex fluorescent PCR assay for the detection of three fastidious respiratory pathogens. PLOS One. 2025. doi:10.1371/journal.pone.0328651

BibTeX
@article{Shi2025,
  author = {Shi, Jingchao and Zhu, Yijun and Chen, Shuyun and Shan, Xiaoyun and Bo, Lihong and Shen, Kai and Chen, Keqiang},
  title = {Methodological establishment and diagnostic value of a multiplex fluorescent PCR assay for the detection of three fastidious respiratory pathogens},
  journal = {PLOS One},
  year = {2025},
  doi = {10.1371/journal.pone.0328651}
}
Kostenlos starten →