EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Impact of ventilation and ambient temperature on COVID-19 transmission in clinic waiting rooms: A computational fluid dynamics approach

Zhankun Zhu, Guosheng Gao, Yaoren Hu, Xiansheng Zhao iD

PLOS One · 2025

DOI: 10.1371/journal.pone.0328154 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, 2025. Verfasst von Zhankun Zhu und 3 weiteren Autor:innen. Beteiligte Einrichtung: General Affairs Department, Ningbo No.2 Hospital, Ningbo, China. Hauptthemen laut MEDLINE: COVID-19, Ventilation. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Zhejiang Provincial Natural Science Foundation of China, Zhejiang Province and Ningbo City Co-constructed Project of Leading Medical &Health Discipline, Research Foundation of Ningbo No.2 Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The ongoing COVID-19 pandemic underscores the necessity of understanding the transmission dynamics in enclosed, high-risk environments, such as clinic waiting rooms. This study used computational fluid dynamics (CFD) to investigate the behavior of virus-laden aerosols in clinic waiting rooms under six different scenarios with various temperatures and ventilation setups, offering insights into practical strategies for enhancing safety in healthcare environments. Key findings demonstrated that effective ventilation, through open windows and mechanical systems, can reduce virus-laden aerosol concentrations by up to 99.3% under optimal conditions (e.g., from 5.80 kg/m 3 to 0.04 kg/m 3 By contrast, poorly ventilated scenarios exhibit significantly higher viral concentrations, which can rise as high as 5.80 kg/m 3 . A novel aspect of this research lies in the comprehensive modeling of human anatomy and aerosol interactions, which enhances the accuracy of viral-trajectory predictions. The practical implications include strategic recommendations for ventilation system design to mitigate transmission risks in clinical settings. These insights provide guidelines for healthcare facility design and emphasize the critical role of environmental control in reducing exposure to airborne pathogens.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

COVID-19VentilationHumansTemperatureHydrodynamicsSARS-CoV-2AerosolsComputer SimulationPandemicsAir Microbiology

Substanzen

Aerosols

Autor:innen und Institutionen

  • General Affairs Department, Ningbo No.2 Hospital, Ningbo, China.
  • Department of Clinical Laboratory, Ningbo No.2 Hospital, Ningbo, China.
  • Department of Liver Disease, Ningbo No.2 Hospital, Ningbo, China.

ORCID-Profile: Xiansheng Zhao

Förderung

  • Zhejiang Provincial Natural Science Foundation of China
  • Zhejiang Province and Ningbo City Co-constructed Project of Leading Medical &Health Discipline
  • Research Foundation of Ningbo No.2 Hospital

Zitieren

APA

Zhu, Z., Gao, G., Hu, Y., & Zhao, X. (2025). Impact of ventilation and ambient temperature on COVID-19 transmission in clinic waiting rooms: A computational fluid dynamics approach. PLOS One. https://doi.org/10.1371/journal.pone.0328154

Vancouver

Zhu Z, Gao G, Hu Y, Zhao X. Impact of ventilation and ambient temperature on COVID-19 transmission in clinic waiting rooms: A computational fluid dynamics approach. PLOS One. 2025. doi:10.1371/journal.pone.0328154

BibTeX
@article{Zhu2025,
  author = {Zhu, Zhankun and Gao, Guosheng and Hu, Yaoren and Zhao, Xiansheng},
  title = {Impact of ventilation and ambient temperature on COVID-19 transmission in clinic waiting rooms: A computational fluid dynamics approach},
  journal = {PLOS One},
  year = {2025},
  doi = {10.1371/journal.pone.0328154}
}
Kostenlos starten →