Development and validation of a nomogram for predicting false negative IGRA results in pulmonary tuberculosis patients using propensity score matching
PLOS One · 2025
DOI: 10.1371/journal.pone.0327767 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift PLOS One, 2025. Verfasst von Feng Zhang und 3 weiteren Autor:innen. Beteiligte Einrichtung: No.2 People's Hospital of Fuyang City, Fuyang Infectious Disease Clinical College of Anhui Medical University, Fuyang, Anhui, China. Hauptthemen laut MEDLINE: Nomograms, Tuberculosis, Pulmonary, Interferon-gamma Release Tests. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fuyang Municipal Health Commission.
Abstract (Originalsprache)
Objective
This study aims to explore factors influencing false-negative results in Interferon-Gamma Release Assay (IGRA) for patients with Pulmonary Tuberculosis (PTB), and develop a nomogram model to predict IGRA false negatives, thereby optimizing clinical diagnosis and treatment decisions.
Methods
Data were collected from January 2023 to September 2024 at the Second People’s Hospital of Fuyang City, involving 143 PTB patients. Among them, 63 patients who were IGRA negative but pathogen positive formed the observation group, while 80 patients who were both IGRA and pathogen positive constituted the control group. Propensity Score Matching (PSM) was used to balance potential confounding factors between the two groups. Clinical characteristics and laboratory indicators were compared, followed by logistic regression analysis to identify independent risk factors affecting IGRA results. A nomogram model was constructed based on these factors and its predictive performance evaluated.
Results
After PSM, each group consisted of 55 patients. The observation group showed significantly lower levels of white blood cell count (WBC), neutrophil count (NEUT), lymphocyte count (LYM), red blood cell count (RBC), hemoglobin (HGB), and albumin (ALB) compared to the control group (P < 0.05). Multivariate analysis ultimately identified RBC, ALB and NLR as independent predictors of IGRA false-negativity. The developed nomogram model demonstrated good calibration (χ² = 4.482, P = 0.811), with an area under the receiver operating characteristic curve (AUC) of 0.764 (95% CI: 0.675−0.853). Decision curve analysis indicated that the net benefit of predicting false-negative IGRA results using this nomogram model was greater than 0 when the threshold probability ranged from 0.15 to 0.95.
Conclusion
Decreased RBC/ALB and elevated NLR may be pivotal factors contributing to false-negative IGRA results in PTB patients. The three-variable nomogram shows enhanced predictive performance, serving as a quantitative tool to identify high-risk cases, particularly for patients with malnutrition or pronounced inflammatory status.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- No.2 People's Hospital of Fuyang City, Fuyang Infectious Disease Clinical College of Anhui Medical University, Fuyang, Anhui, China.
ORCID-Profile: Wei Zhang
Förderung
- Fuyang Municipal Health Commission
Zitieren
APA
Zhang, F., Gao, Y., Li, T., & Zhang, W. (2025). Development and validation of a nomogram for predicting false negative IGRA results in pulmonary tuberculosis patients using propensity score matching. PLOS One. https://doi.org/10.1371/journal.pone.0327767
Vancouver
Zhang F, Gao Y, Li T, Zhang W. Development and validation of a nomogram for predicting false negative IGRA results in pulmonary tuberculosis patients using propensity score matching. PLOS One. 2025. doi:10.1371/journal.pone.0327767
BibTeX
@article{Zhang2025,
author = {Zhang, Feng and Gao, Yong and Li, Tuantuan and Zhang, Wei},
title = {Development and validation of a nomogram for predicting false negative IGRA results in pulmonary tuberculosis patients using propensity score matching},
journal = {PLOS One},
year = {2025},
doi = {10.1371/journal.pone.0327767}
}
EUVIMED