Calibrated muscle models improve tracking simulations without enhancing gait predictions
PLOS One · 2025
DOI: 10.1371/journal.pone.0327172 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, 2025. Verfasst von Filippo Maceratesi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering and Institute for Research and Innovation in Health (IRIS), Universitat Politècnica de Catalunya - BarcelonaTech…. Hauptthemen laut MEDLINE: Gait, Muscle, Skeletal, Models, Biological. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: AGAUR-FI ajuts, Agencia Estatal de Investigación (AEI) and the European Regional Development Fund.
Abstract (Originalsprache)
Objectives
This study presents two main aims: (i) to assess functionally-calibrated musculoskeletal models (FCMs) in both tracking and predictive simulations of human motion, against non-linearly scaled models (NSMs), and (ii) to examine the effects of three different variations of our baseline functional calibration approach on the results of tracking and predictive simulations.
Methods
Motion capture experiments of six functional activities were performed with three healthy subjects. The musculotendon (MT) parameters of 18 muscles per leg were estimated using an optimal control problem. A baseline problem formulation and three variations were developed to generate four different FCMs per subject. Then, the FCMs were compared against NSMs in tracking simulations of the motions excluded from the calibration and fully-predictive simulations of gait.
Results
In the tracking simulations, the FCMs led to more accurate joint torques estimations. Including gait in the calibration problems improved the knee torques accuracy (normalised root mean square error: 0.31 ± 0.11), compared to the baseline calibration (normalised root mean square error: 0.70 ± 0.21). Regarding the gait predictive simulations, the NSMs consistently yielded more accurate subtalar inversion/eversion torques and knee flexion angles, compared to the FCMs. The accuracy of the predicted muscle excitations was generally consistent between NSMs and FCMs.
Conclusion
The results suggest that, while the FCMs led to more accurate joint torques estimations in the tracking simulations, they did not outperform the NSMs in the fully-predictive gait simulations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Mechanical Engineering and Institute for Research and Innovation in Health (IRIS), Universitat Politècnica de Catalunya - BarcelonaTech (UPC), Barcelona, Spain.
- Institut de Recerca Sant Joan de Déu, Esplugues de Llobregat, Barcelona, Spain.
ORCID-Profile: Filippo Maceratesi, Josep M Font-Llagunes
Förderung
- AGAUR-FI ajuts
- Agencia Estatal de Investigación (AEI) and the European Regional Development Fund
Zitieren
APA
Maceratesi, F., Febrer-Nafría, M., & Font-Llagunes, J. M. (2025). Calibrated muscle models improve tracking simulations without enhancing gait predictions. PLOS One. https://doi.org/10.1371/journal.pone.0327172
Vancouver
Maceratesi F, Febrer-Nafría M, Font-Llagunes JM. Calibrated muscle models improve tracking simulations without enhancing gait predictions. PLOS One. 2025. doi:10.1371/journal.pone.0327172
BibTeX
@article{Maceratesi2025,
author = {Maceratesi, Filippo and Febrer-Nafría, Míriam and Font-Llagunes, Josep M},
title = {Calibrated muscle models improve tracking simulations without enhancing gait predictions},
journal = {PLOS One},
year = {2025},
doi = {10.1371/journal.pone.0327172}
}
EUVIMED