Validierungsstudie in der Zeitschrift PLOS One, online erschienen am 13.06.2025. Verfasst von Peemongkon Wattananon und 3 weiteren Autor:innen. Beteiligte Einrichtung: Spine Biomechanics Laboratory, Faculty of Physical Therapy, Mahidol University, Nakhon Pathom, Thailand. Hauptthemen laut MEDLINE: Low Back Pain, Lumbar Vertebrae. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Council of Thailand.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Patients with chronic non-specific low back pain (CNLBP) demonstrate movement control impairment (MCI) based on a 6-item motor control test (MCT) battery, suggesting its potential clinical utility.

Objectives

This study aimed to determine the criterion-related validity of the 6-item MCT battery in discriminating MCI among individuals with CNLBP, a history of low back pain (HxLBP), and no low back pain (NoLBP).

Methods

One hundred forty-one participants aged 20–40 years (47 participants per group) were recruited. The MCT battery (the waiter’s bow, pelvic tilt, sitting knee extension, quadruped rocking forward, quadruped rocking backward, prone knee flexion) was rated using different rating methods, including individual tests, summation, and direction-specific tests. A 2x2 contingency table using a known group against the rating result was used to calculate chi-square, sensitivity, specificity, and positive and negative likelihood ratios for each pair separately.

Results

Chi-square tests demonstrated significant associations ( P < 0.05) between MCT and CNLBP when compared against NoLBP. In addition, the waiter’s bow and flexion-specific tests demonstrated high sensitivity (81% and 72%, respectively), while sitting knee extension, prone knee flexion, and summation demonstrated high specificity (70%, 70%, and 89%, respectively).

Conclusion

Findings suggest the acceptable validity of the MCT battery when compared between CNLBP and NoLBP. The waiter’s bow and flexion-specific tests effectively ruled out individuals with NoLBP with negative results, while sitting knee extension, prone knee flexion, and summation effectively ruled in the individuals with CNLBP with positive results. These findings highlight the clinical utility of these tests in assessing MCI in the lumbar spine.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Low Back PainLumbar VertebraeHumansFemaleMaleAdultMovementYoung AdultReproducibility of Results

Autor:innen und Institutionen

  • Spine Biomechanics Laboratory, Faculty of Physical Therapy, Mahidol University, Nakhon Pathom, Thailand.
  • Physiotherapy Department, Tishk International University, Erbil, Kurdistan Region, Iraq.

ORCID-Profile: Peemongkon Wattananon

Förderung

  • National Research Council of Thailand

Zitieren

APA

Wattananon, P., Ibrahim, A. A., Kongoun, S., & Klahan, K. (2025). Validity of a 6-item movement control test battery for evaluation of movement control impairment in the lumbar spine. PLOS One, 20(6), e0325996. https://doi.org/10.1371/journal.pone.0325996

Vancouver

Wattananon P, Ibrahim AA, Kongoun S, Klahan K. Validity of a 6-item movement control test battery for evaluation of movement control impairment in the lumbar spine. PLOS One. 2025;20(6):e0325996. doi:10.1371/journal.pone.0325996

BibTeX
@article{Wattananon2025,
  author = {Wattananon, Peemongkon and Ibrahim, Aminu Alhassan and Kongoun, Sasithorn and Klahan, Katayan},
  title = {Validity of a 6-item movement control test battery for evaluation of movement control impairment in the lumbar spine},
  journal = {PLOS One},
  year = {2025},
  volume = {20},
  number = {6},
  pages = {e0325996},
  doi = {10.1371/journal.pone.0325996}
}
Kostenlos starten →