Diagnostic concordance of GeneXpert HCV VL fingerstick and GeneXpert HCV viral load with RT-PCR in POCT settings among hemodialysis patients
PLOS One · 2026
DOI: 10.1371/journal.pone.0324671 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, 2026. Verfasst von Andri Sanityoso Sulaiman und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Hepatobiliary, Department of Internal Medicine, Faculty of Medicine Universitas Indonesia - Dr. Cipto Mangunkusumo Hospital, Jakarta, Ind…. Hauptthemen laut MEDLINE: Renal Dialysis, Hepacivirus, Viral Load, Hepatitis C. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Hepatitis C virus (HCV) remains a significant global health concern, particularly among high-risk populations such as patients undergoing hemodialysis. Although nucleic acid testing (NAT) using RT-PCR remains the gold standard for HCV RNA detection, its centralized laboratory workflow limits accessibility. Point-of-care molecular testing (PoCT), such as the GeneXpert Fingerstick assay, offers a decentralized alternative for HCV RNA quantification. However, its analytical concordance with reference methods in Indonesian settings remains limited.
Methods
This study was a cross-sectional analytical concordance study involving 57 patients with chronic kidney disease (CKD) undergoing hemodialysis at Cipto Mangunkusumo and Pelni Hospitals in Jakarta. Each participant underwent HCV RNA testing using three methods: GeneXpert HCV VL Fingerstick, GeneXpert HCV VL Plasma, and Cobas TaqMan RT-PCR (as the reference standard). Agreement among methods was assessed using sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and Cohen’s κ coefficient. Correlation for quantifiable values was evaluated using linear regression analysis.
Results
Both GeneXpert methods showed perfect concordance with the Cobas TaqMan RT-PCR, with sensitivity, specificity, PPV, and NPV all at 100%. Agreement analysis yielded a Cohen’s κ of 1.000 ( p < 0.001) for both comparisons. Quantitative correlation between methods was also strong ( R² > 0.95).
Conclusion
The GeneXpert HCV VL Fingerstick assay demonstrates excellent analytical agreement with conventional molecular testing and may serve as a simple, practical, decentralized alternative for monitoring HCV RNA in hemodialysis patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Division of Hepatobiliary, Department of Internal Medicine, Faculty of Medicine Universitas Indonesia - Dr. Cipto Mangunkusumo Hospital, Jakarta, Indonesia.
- Division of Nephrology and Hypertension, Department of Internal Medicine, Faculty of Medicine Universitas Indonesia - Dr. Cipto Mangunkusumo Hospital, Jakarta, Indonesia.
ORCID-Profile: Andri Sanityoso Sulaiman
Zitieren
APA
Sulaiman, A. S., Nugroho, P., Bahri, D. R., & Rachmani, D. (2026). Diagnostic concordance of GeneXpert HCV VL fingerstick and GeneXpert HCV viral load with RT-PCR in POCT settings among hemodialysis patients. PLOS One. https://doi.org/10.1371/journal.pone.0324671
Vancouver
Sulaiman AS, Nugroho P, Bahri DR, Rachmani D. Diagnostic concordance of GeneXpert HCV VL fingerstick and GeneXpert HCV viral load with RT-PCR in POCT settings among hemodialysis patients. PLOS One. 2026. doi:10.1371/journal.pone.0324671
BibTeX
@article{Sulaiman2026,
author = {Sulaiman, Andri Sanityoso and Nugroho, Pringgodigdo and Bahri, Darlene Raudhatul and Rachmani, Desti},
title = {Diagnostic concordance of GeneXpert HCV VL fingerstick and GeneXpert HCV viral load with RT-PCR in POCT settings among hemodialysis patients},
journal = {PLOS One},
year = {2026},
doi = {10.1371/journal.pone.0324671}
}
EUVIMED