EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Inter-monitor reliability and validity of the fibion accelerometers in a laboratory-based study of functional activities

Ashokan Arumugam iD, Zaineb Ghannami, Mahnaz Mahallati, Hala Al-Shams, Shaza Ahmed, Hager Khaled, Maha Hussein, Hanan Youssef Alkalih, Alexander H K Montoye, Kimberly Clevenger, Arto J Pesola iD

PLOS One · 20.05.2025 · 20 (5) · e0324555

DOI: 10.1371/journal.pone.0324555 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift PLOS One, online erschienen am 20.05.2025. Verfasst von Ashokan Arumugam und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physiotherapy, College of Health Sciences, University of Sharjah, Sharjah, United Arab Emirates. Hauptthemen laut MEDLINE: Accelerometry, Exercise. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Accelerometer-based physical activity monitors are designed for placement on several body locations, with popular sites being the wrist, waist/hip, and thigh. Thigh placement is particularly valued for its accuracy in measuring postures and related energy expenditures. However, exploring the outcomes of different thigh wear locations remains an area for further research. This study investigated the inter-monitor reliability of Fibion accelerometers for energy expenditure and activity type classification, and their validity by comparing the Fibion’s activity classification against direct observation of a structured activity protocol as the reference standard.

Methods

Thirty healthy, young adults (aged 21.83 ± 2.80 years; 15 women) wore six Fibion accelerometers on three locations (proximal thigh, 10 cm above the patella, and the front trouser pocket) on both thighs while performing 11 functional activities for 70 minutes in a laboratory setting. Inter-monitor reliability for measuring energy expenditure, activity type and intensity, and accuracy for activity type and intensity classification of the pre-defined functional activities were assessed. Validity was assessed for classifying activity type and intensity.

Results

Reliability estimates (intraclass correlation coefficients (ICC 3, k)) implied good to excellent inter-monitor reliability for measuring energy expenditure during nearly all activities. Furthermore, energy expenditure measurements were equivalent between accelerometers in both trouser pockets, and proximal and distal thighs within a bound of ±.1.60 kcal/min. However, the right pocket was not equivalent to either the right proximal thigh or the right distal thigh. The mean activity classification accuracy ranged from 87–92% for activity type and 91–94% for activity intensity for the chosen activities, irrespective of the accelerometer location or side of the body (right vs. left).

Conclusion

The Fibion accelerometers reliably measure energy expenditure and accurately classify activity type/intensity for nearly all functional activities, regardless of the thigh wear location or side of the body. However, interchanging pocket and thigh placements is not recommended. Similar studies in free-living settings are further warranted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AccelerometryExerciseHumansFemaleMaleEnergy MetabolismYoung AdultReproducibility of ResultsAdultThigh

Autor:innen und Institutionen

  • Department of Physiotherapy, College of Health Sciences, University of Sharjah, Sharjah, United Arab Emirates.
  • Neuromusculoskeletal Rehabilitation Research Group, RIMHS - Research Institute of Medical and Health Sciences, University of Sharjah, Sharjah, United Arab Emirates.
  • Sustainable Engineering Asset Management Research Group, RISE - Research Institute of, Sciences and Engineering, University of Sharjah, Sharjah, United Arab Emirates.
  • Adjunct Faculty, Department of Physiotherapy, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, India.
  • Department of Integrative Physiology and Health Science, Alma College, Alma, Michigan, United States of America.
  • Department of Kinesiology and Health Science, College of Education and Human Services, Utah State University, Logan, Utah United States of America.

ORCID-Profile: Ashokan Arumugam, Arto J Pesola

Zitieren

APA

Arumugam, A., Ghannami, Z., Mahallati, M., Al-Shams, H., Ahmed, S., Khaled, H., Hussein, M., Alkalih, H. Y., Montoye, A. H. K., Clevenger, K., & Pesola, A. J. (2025). Inter-monitor reliability and validity of the fibion accelerometers in a laboratory-based study of functional activities. PLOS One, 20(5), e0324555. https://doi.org/10.1371/journal.pone.0324555

Vancouver

Arumugam A, Ghannami Z, Mahallati M, Al-Shams H, Ahmed S, Khaled H, et al. Inter-monitor reliability and validity of the fibion accelerometers in a laboratory-based study of functional activities. PLOS One. 2025;20(5):e0324555. doi:10.1371/journal.pone.0324555

BibTeX
@article{Arumugam2025,
  author = {Arumugam, Ashokan and Ghannami, Zaineb and Mahallati, Mahnaz and Al-Shams, Hala and Ahmed, Shaza and Khaled, Hager and Hussein, Maha and Alkalih, Hanan Youssef and Montoye, Alexander H K and Clevenger, Kimberly and Pesola, Arto J},
  title = {Inter-monitor reliability and validity of the fibion accelerometers in a laboratory-based study of functional activities},
  journal = {PLOS One},
  year = {2025},
  volume = {20},
  number = {5},
  pages = {e0324555},
  doi = {10.1371/journal.pone.0324555}
}
Kostenlos starten →