Pupil responses to melanopsin-isolating stimuli as a potential diagnostic biomarker for glaucoma
PLOS One · 2025
DOI: 10.1371/journal.pone.0324373 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS One, 2025. Verfasst von Jonathan Denniss und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Optometry & Vision Science, University of Bradford, Bradford, United Kingdom. Hauptthemen laut MEDLINE: Rod Opsins, Pupil, Glaucoma. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Glaucoma UK.
Abstract (Originalsprache)
Purpose
To test whether differences in pupil responses to melanopsin-isolating spectral stimuli in glaucoma may be useful as a diagnostic biomarker.
Methods
Spectral stimuli were presented to 20 glaucoma and 15 age-similar healthy control participants. Stimuli were pairs of silent-substitution spectra designed to provide (1) equal stimulation to cone photoreceptors but maximum (~325%) contrast to melanopsin or (2) equal stimulation to melanopsin but ~325% contrast to cones. Narrowband long-wavelength/red (657 nm) and short-wavelength/blue (471 nm) pulses were also presented from a dark background to 16 glaucoma and 12 control participants. Pulses lasted 3 seconds and pupil size was measured for 15 seconds. Pupil response metrics were compared by t-test and relationships with visual field and OCT summary indices were assessed by Spearman’s rank correlation. Diagnostic accuracy was measured by area under the receiver operating characteristic curve (AUC).
Results
Pupil constriction was more persistent after pulse offset for the melanopsin-directed stimulus (2% mean paired difference 6s post-pulse offset, p < 0.001). All pupil parameters were similar between groups (p = 0.04–0.90) for all stimuli. Correlations between pupil response parameters and visual field summary indices and circumpapillary retinal nerve fibre layer thickness were weak (rho 0.02–0.57, all p > 0.05). Diagnostic accuracy for all pupil parameters was poor, with AUC 95% confidence intervals overlapping 0.5 for all but time to maximal constriction for the cone-directed stimulus.
Conclusions
Pupil responses to melanopsin-isolating spectra were similar between glaucoma and control participants. Pupillary responses to melanopsin-isolating silent substitution spectra are unlikely to be useful as a diagnostic biomarker for glaucoma.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- School of Optometry & Vision Science, University of Bradford, Bradford, United Kingdom.
- Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom.
- School of Psychology, Philosophy and Language Sciences, University of Edinburgh, Edinburgh, United Kingdom.
- Max Planck Research Group Translational Sensory & Circadian Neuroscience, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.
- TUM School of Medicine and Health, Department Health and Sports Sciences, Chronobiology & Health, Technical University of Munich, Munich, Germany.
- TUM Institute for Advanced Study (TUM-IAS), Technical University of Munich, Garching, Germany.
ORCID-Profile: Jonathan Denniss, Riccardo Cheloni
Förderung
- Glaucoma UK
Zitieren
APA
Denniss, J., Cheloni, R., Martin, J. T., & Spitschan, M. (2025). Pupil responses to melanopsin-isolating stimuli as a potential diagnostic biomarker for glaucoma. PLOS One. https://doi.org/10.1371/journal.pone.0324373
Vancouver
Denniss J, Cheloni R, Martin JT, Spitschan M. Pupil responses to melanopsin-isolating stimuli as a potential diagnostic biomarker for glaucoma. PLOS One. 2025. doi:10.1371/journal.pone.0324373
BibTeX
@article{Denniss2025,
author = {Denniss, Jonathan and Cheloni, Riccardo and Martin, Joel T and Spitschan, Manuel},
title = {Pupil responses to melanopsin-isolating stimuli as a potential diagnostic biomarker for glaucoma},
journal = {PLOS One},
year = {2025},
doi = {10.1371/journal.pone.0324373}
}