EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Analysis of axial shortening induced by orthokeratology lenses and its mechanical mechanisms

Zhao-Yang Meng, Lin Yang, Peng Zhou iD

PLOS One · 2025

DOI: 10.1371/journal.pone.0323546 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, 2025. Verfasst von Zhao-Yang Meng und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Beijing Friendship Hospital, Capital Medical University, Beijing, China. Hauptthemen laut MEDLINE: Orthokeratologic Procedures, Myopia, Axial Length, Eye, Contact Lenses. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aims to examine the short-term axial shortening effects of orthokeratology (ortho-K) lenses and investigate their mechanical mechanisms.

Methods

We conducted a retrospective analysis on 80 myopic children, aged 8–18, who wore ortho-K lenses for one week. Axial lengths were measured pre- and post-treatment using AL-Scan Optical Biometer. We developed a finite element model of the eye using ABAQUS software to explore mechanical changes.

Results

A significant reduction in axial length was observed after one week of ortho-K lens wear, with an average decrease of 0.028 ± 0.032 mm (P = 4.02 x 10 -11 ). Approximately 82.5% of participants exhibited axial length reduction. The biomechanical model indicated that ortho-K lenses exerted forces altering the tension dynamics within the ocular structure, notably decreasing tension in the posterior ciliary muscle-lens complex. This differential change in tension may account for the mechanical basis of the observed short-term reduction in axial length.

Conclusion

Orthokeratology lenses induce a short-term shortening in axial length, likely due to mechanical changes in ocular tension dynamics. The finite element model suggests that these lenses decrease posterior ciliary-lens complex tension, leading to axial shortening. These findings enhance comprehension of the mechanical basis for myopia control via ortho-K treatment, highlighting potential avenues for further applied research in myopia management.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Orthokeratologic ProceduresMyopiaAxial Length, EyeContact LensesHumansChildAdolescentMaleFemaleRetrospective StudiesBiomechanical PhenomenaFinite Element Analysis

Autor:innen und Institutionen

  • Department of Ophthalmology, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
  • Department of Ophthalmology, Visionly Plus Eye Hospital, Beijing, China.
  • Department of Ophthalmology, Parkway Gleneagles Medical and Surgical Center, Shanghai, China.
  • Department of Ophthalmology, Parkway Hong Qiao Medical Center, Shanghai, China.

ORCID-Profile: Peng Zhou

Zitieren

APA

Meng, Z. Y., Yang, L., & Zhou, P. (2025). Analysis of axial shortening induced by orthokeratology lenses and its mechanical mechanisms. PLOS One. https://doi.org/10.1371/journal.pone.0323546

Vancouver

Meng ZY, Yang L, Zhou P. Analysis of axial shortening induced by orthokeratology lenses and its mechanical mechanisms. PLOS One. 2025. doi:10.1371/journal.pone.0323546

BibTeX
@article{Meng2025,
  author = {Meng, Zhao-Yang and Yang, Lin and Zhou, Peng},
  title = {Analysis of axial shortening induced by orthokeratology lenses and its mechanical mechanisms},
  journal = {PLOS One},
  year = {2025},
  doi = {10.1371/journal.pone.0323546}
}
Kostenlos starten →