EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieMultizentrische StudieOpen Access · CC BY 4.0

Spinal needles versus conventional needles for fine-needle aspiration biopsy of thyroid nodules—A multicenter randomized controlled trial

Kasper Daugaard Larsen iD, Gitte Bjørn Hvilsom iD, Tobias Vennervald Andersen, Preben Homøe, Finn Noe Bennedbæk, Jens Pedersen, Lena Bjergved Sigurd, Jens Jessen Warm, Katalin Kiss, Giedrius Lelkaitis, Luise Andersen, Marie Røsland Rosenørn und 6 weitere

PLOS One · 2025

DOI: 10.1371/journal.pone.0321043 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift PLOS One, 2025. Verfasst von Kasper Daugaard Larsen und 17 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otorhinolaryngology, Head and Neck Surgery and Audiology, Rigshospitalet - Copenhagen University Hospital, Copenhagen, Denmark. Hauptthemen laut MEDLINE: Thyroid Nodule, Needles. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Erik og Susanna Olesens Almenvelgørende Fond, Rigshospitalet.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Ultrasound-guided fine-needle aspiration biopsy (FNAB) is essential for evaluating thyroid nodules but often yields inadequate samples, leading to repeated procedures, increased discomfort, and higher costs. Previous non-randomized studies found promising results of spinal needles to improve diagnostic adequacy. Therefore, we conducted a multicenter randomized controlled trial to validate these findings.

Methods

Between July 1 st , 2021, and April 13 th , 2023, patients with suspicious thyroid nodules were randomized to receive FNAB with either a 25G spinal needle or conventional needle. The primary outcome was the rate of adequate diagnostic cytology. Secondary outcomes included procedure-related pain, sensitivity and specificity of FNAB, and adverse events.

Results

A total of 359 patients (75.6% female), with a mean age of 59.7 years (range 23−94) were randomized. The rate of adequate diagnostic FNAB was 86.2% (156/181) for the spinal group compared to 84.8% (151/178) for the control group (OR 1.01; 95% CI: 0.95–1.08). The mean pain scale score was 4.0 (SD = 1.8) in the spinal group and 3.9 (SD = 2.0) in the control group ( p = 0.40). No complications were observed in either group. We found a significantly better cytological adequacy rate of FNABs performed by physicians with more than four years of experience in the procedure (OR=1.07; 95% CI, 1.01–1.14).

Conclusions

No significant improvement was found using spinal needles with a stylet compared to conventional needles. Given the significantly higher cost of spinal needles and comparable diagnostic outcomes, their routine use for thyroid FNAB is not recommended.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Thyroid NoduleNeedlesHumansFemaleMiddle AgedMaleAdultAgedBiopsy, Fine-NeedleAged, 80 and overYoung Adult

Autor:innen und Institutionen

  • Department of Otorhinolaryngology, Head and Neck Surgery and Audiology, Rigshospitalet - Copenhagen University Hospital, Copenhagen, Denmark.
  • Department of Otorhinolaryngology, Head and Neck Surgery, Zealand University Hospital, Køge, Denmark.
  • Institute of Clinical Medicine, Faculty of Health Sciences, Copenhagen University, Copenhagen, Denmark.
  • Department of Endocrinology and Metabolism, Herlev and Gentofte Hospital, Herlev, Denmark.
  • Department of Pathology, Rigshospitalet - Copenhagen University Hospital, Copenhagen, Denmark.
  • Department of Pathology, Zealand University Hospital, Roskilde, Denmark.

ORCID-Profile: Kasper Daugaard Larsen, Gitte Bjørn Hvilsom, Mikkel Kaltoft

Förderung

  • Erik og Susanna Olesens Almenvelgørende Fond
  • Rigshospitalet

Zitieren

APA

Larsen, K. D., Hvilsom, G. B., Andersen, T. V., Homøe, P., Bennedbæk, F. N., Pedersen, J., Sigurd, L. B., Warm, J. J., Kiss, K., Lelkaitis, G., Andersen, L., Rosenørn, M. R., Hegedüs, L., Ersbøll, A. K., Lomholt, A. F., Kaltoft, M., Hahn, C. H., & Todsen, T. (2025). Spinal needles versus conventional needles for fine-needle aspiration biopsy of thyroid nodules—A multicenter randomized controlled trial. PLOS One. https://doi.org/10.1371/journal.pone.0321043

Vancouver

Larsen KD, Hvilsom GB, Andersen TV, Homøe P, Bennedbæk FN, Pedersen J, et al. Spinal needles versus conventional needles for fine-needle aspiration biopsy of thyroid nodules—A multicenter randomized controlled trial. PLOS One. 2025. doi:10.1371/journal.pone.0321043

BibTeX
@article{Larsen2025,
  author = {Larsen, Kasper Daugaard and Hvilsom, Gitte Bjørn and Andersen, Tobias Vennervald and Homøe, Preben and Bennedbæk, Finn Noe and Pedersen, Jens and Sigurd, Lena Bjergved and Warm, Jens Jessen and Kiss, Katalin and Lelkaitis, Giedrius and Andersen, Luise and Rosenørn, Marie Røsland and Hegedüs, Laszlo and Ersbøll, Annette Kjær and Lomholt, Anne Fog and Kaltoft, Mikkel and Hahn, Christoffer Holst and Todsen, Tobias},
  title = {Spinal needles versus conventional needles for fine-needle aspiration biopsy of thyroid nodules—A multicenter randomized controlled trial},
  journal = {PLOS One},
  year = {2025},
  doi = {10.1371/journal.pone.0321043}
}
Kostenlos starten →