Computer-based quantitative image texture analysis using multi-collinearity diagnosis in chest X-ray images
PLOS ONE · 2025
DOI: 10.1371/journal.pone.0320706 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2025. Verfasst von Antonio Quintero-Rincón und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Data Science, Data Science and AI Laboratory, Catholic University of Argentina (UCA), Buenos Aires, Argentina. Hauptthemen laut MEDLINE: COVID-19, Radiography, Thoracic, Image Processing, Computer-Assisted, Radiographic Image Interpretation, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 78 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Despite tremendous efforts devoted to the area, image texture analysis is still an open research field. This paper presents an algorithm and experimental results demonstrating the feasibility of developing automated tools to detect abnormal X-ray images based on tissue attenuation. Specifically, this work proposes using the variability characterised by singular values and conditional indices extracted from the singular value decomposition (SVD) as image texture features. In addition, the paper introduces a “tuning weight" parameter to consider the variability of the X-ray attenuation in tissues affected by pathologies. This weight is estimated using the coefficient of variation of the minimum covariance determinant from the bandwidth yielded by the non-parametric distribution of variance-decomposition proportions of the SVD. When multiplied by the two features (singular values and conditional indices), this single parameter acts as a tuning weight, reducing misclassification and improving the classic performance metrics, such as true positive rate, false negative rate, positive predictive values, false discovery rate, area-under-curve, accuracy rate, and total cost. The proposed method implements an ensemble bagged trees classification model to classify X-ray chest images as COVID-19, viral pneumonia, lung opacity, or normal. It was tested using a challenging, imbalanced chest X-ray public dataset. The results show an accuracy of 88% without applying the tuning weight and 99% with its application. The proposed method outperforms state-of-the-art methods, as attested by all performance metrics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Data Science, Data Science and AI Laboratory, Catholic University of Argentina (UCA), Buenos Aires, Argentina.
- Department of Computer Sciences, Catholic University of Argentina (UCA), Buenos Aires, Argentina.
- "Prof. Dr. Juan P. Garrahan" Pediatric Hospital, Medical Image Department, Buenos Aires, Argentina.
- MACS School, Heriot-Watt University, Dubai, United Arab Emirates.
ORCID-Profile: Antonio Quintero-Rincón, Ricardo Di-Pasquale, Hadj Batatia
Zitieren
APA
Quintero-Rincón, A., Di-Pasquale, R., Quintero-Rodríguez, K., & Batatia, H. (2025). Computer-based quantitative image texture analysis using multi-collinearity diagnosis in chest X-ray images. PLOS ONE. https://doi.org/10.1371/journal.pone.0320706
Vancouver
Quintero-Rincón A, Di-Pasquale R, Quintero-Rodríguez K, Batatia H. Computer-based quantitative image texture analysis using multi-collinearity diagnosis in chest X-ray images. PLOS ONE. 2025. doi:10.1371/journal.pone.0320706
BibTeX
@article{QuinteroRincn2025,
author = {Quintero-Rincón, Antonio and Di-Pasquale, Ricardo and Quintero-Rodríguez, Karina and Batatia, Hadj},
title = {Computer-based quantitative image texture analysis using multi-collinearity diagnosis in chest X-ray images},
journal = {PLOS ONE},
year = {2025},
doi = {10.1371/journal.pone.0320706}
}
EUVIMED