Deep learning-based acceleration of muscle water T2 mapping in patients with neuromuscular diseases by more than 50% - translating quantitative MRI from research to clinical routine
PLOS ONE · 2025
DOI: 10.1371/journal.pone.0318599 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2025. Verfasst von Joachim Schmitt und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Neuroradiology, School of Medicine and Health, TUM Klinikum Rechts der Isar, Technical University of Muni…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Deep Learning, Muscle, Skeletal, Neuromuscular Diseases. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: School of Medicine, TUM.
Abstract (Originalsprache)
Background
Quantitative muscle water T2 (T2 w ) mapping is regarded as a biomarker for disease activity and response to treatment in neuromuscular diseases (NMD). However, the implementation in clinical settings is limited due to long scanning times and low resolution. Using artificial intelligence (AI) to accelerate MR image acquisition offers a possible solution. Combining compressed sensing and parallel imaging with AI-based reconstruction, known as CSAI (SmartSpeed, Philips Healthcare), allows for the generation of high-quality, weighted MR images in a shorter scan time. However, CSAI has not yet been investigated for quantitative MRI. Therefore, in the present work we assessed the performance of CSAI acceleration for T2 w mapping compared to standard acceleration with SENSE.
Methods
T2 w mapping of the thigh muscles, based on T2-prepared 3D TSE with SPAIR fat suppression, was performed using standard SENSE (acceleration factor of 2; 04:35 min; SENSE) and CSAI (acceleration factor of 5; 01:57 min; CSAI 5x) in ten patients with facioscapulohumeral muscular dystrophy (FSHD). Subjects were scanned in two consecutive sessions (14 days in between). In each dataset, six regions of interest were placed in three thigh muscles bilaterally. SENSE and CSAI 5x acceleration were compared for i) image quality using apparent signal- and contrast-to-noise ratio (aSNR/aCNR), ii) diagnostic agreement of T2w values, and iii) intra- and inter-session reproducibility. Results aSNR and aCNR of SENSE and CSAI 5x scans were not significantly different ( p > 0.05). An excellent agreement of SENSE and CSAI 5x T2 w values was shown (r = 0.99; ICC = 0.992). T2 w mapping with both acceleration methods showed excellent, matching intra-method reproducibility.
Conclusion
AI-based acceleration of CS data allows for scan time reduction of more than 50% for T2 w mapping in the thigh muscles of NMD patients without compromising quantitative validity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Neuroradiology, School of Medicine and Health, TUM Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany.
- Department of Diagnostic and Interventional Radiology, School of Medicine and Health, TUM Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany.
- Philips GmbH, Hamburg, Germany.
- Department of Neurology, Friedrich-Baur-Institute, LMU Munich, Munich, Germany.
- Department of Neurology, School of Medicine and Health, TUM Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany.
- Department of Radiology, LMU University Hospital, LMU Munich, Munich, Germany.
ORCID-Profile: Kilian Weiss, Jan S Kirschke, Sarah Schlaeger
Förderung
- School of Medicine, TUM
Zitieren
APA
Schmitt, J., Weidlich, D., Weiss, K., Stelter, J., Montagnese, F., Deschauer, M., Schoser, B., Zimmer, C., Karampinos, D. C., Kirschke, J. S., & Schlaeger, S. (2025). Deep learning-based acceleration of muscle water T2 mapping in patients with neuromuscular diseases by more than 50% - translating quantitative MRI from research to clinical routine. PLOS ONE. https://doi.org/10.1371/journal.pone.0318599
Vancouver
Schmitt J, Weidlich D, Weiss K, Stelter J, Montagnese F, Deschauer M, et al. Deep learning-based acceleration of muscle water T2 mapping in patients with neuromuscular diseases by more than 50% - translating quantitative MRI from research to clinical routine. PLOS ONE. 2025. doi:10.1371/journal.pone.0318599
BibTeX
@article{Schmitt2025,
author = {Schmitt, Joachim and Weidlich, Dominik and Weiss, Kilian and Stelter, Jonathan and Montagnese, Federica and Deschauer, Marcus and Schoser, Benedikt and Zimmer, Claus and Karampinos, Dimitrios C and Kirschke, Jan S and Schlaeger, Sarah},
title = {Deep learning-based acceleration of muscle water T2 mapping in patients with neuromuscular diseases by more than 50% - translating quantitative MRI from research to clinical routine},
journal = {PLOS ONE},
year = {2025},
doi = {10.1371/journal.pone.0318599}
}
EUVIMED