EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Modeling and simulation of blood flow in unhealthy elliptic arteries with computational fluid dynamics approach

Abdul Wahab, Muhammad Imran Asjad, Muhammad Bilal Riaz, Jamil Abbas Haider iD

PLOS ONE · 08.04.2025 · 20 (4) · e0317989

DOI: 10.1371/journal.pone.0317989 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 08.04.2025. Verfasst von Abdul Wahab und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mathematics, University of Management and Technology, Lahore, Pakistan. Hauptthemen laut MEDLINE: Computer Simulation, Hydrodynamics, Models, Cardiovascular, Arteries. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates the influence of varying degrees of stenosis on blood flow within elliptic arteries, emphasizing the critical role of artery shape in clinical evaluations as opposed to the commonly studied circular arteries. Unlike prior work, this research offers a precise definition of stenosis by incorporating the measured length, height, and position of the narrowing. Employing the non-Newtonian Williamson fluid model, we conducted comprehensive numerical simulations to examine blood flow through four distinct stenosis formations. The novelty of this work lies in its accurate modeling of stenosis and use of advanced mesh generation, combined with commercial software and the finite volume method, to capture detailed hemodynamic behavior. Visualized results, including pressure profiles, velocity line graphs, and streamlines, further underscore the distinctive flow dynamics shaped by the elliptic geometry. Key findings of the obtained results reveal that blood velocity peaks near the stenosis and drops significantly post-stenosis, with notable variations in flow patterns, energy loss, and pressure distribution across different stenosis types. Further, higher velocity of blood flow is observed in elliptic arteries in comparison with circular ones. In the area of the high corners of stenotic segments, the pressure profile reaches high values. As a result of the narrowing of the arterial cross-section, the varied time shows that the post-stenotic segment of the artery has a higher pressure than the pre-stenotic section. The varied time suggests that an axially symmetric profile will eventually be the norm for the flow within the arterial portion. These insights have profound implications for improving clinical diagnosis and treatment strategies for conditions related to stenosed elliptic arteries.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computer SimulationHydrodynamicsModels, CardiovascularArteriesHumansBlood Flow VelocityHemodynamicsConstriction, Pathologic

Autor:innen und Institutionen

  • Department of Mathematics, University of Management and Technology, Lahore, Pakistan.
  • IT4Innovations, VSB - Technical University of Ostrava, Ostrava, Czech Republic.
  • Abdus Salam School of Mathematical Sciences, Government College University Lahore, Lahore, Pakistan.

ORCID-Profile: Jamil Abbas Haider

Zitieren

APA

Wahab, A., Asjad, M. I., Riaz, M. B., & Haider, J. A. (2025). Modeling and simulation of blood flow in unhealthy elliptic arteries with computational fluid dynamics approach. PLOS ONE, 20(4), e0317989. https://doi.org/10.1371/journal.pone.0317989

Vancouver

Wahab A, Asjad MI, Riaz MB, Haider JA. Modeling and simulation of blood flow in unhealthy elliptic arteries with computational fluid dynamics approach. PLOS ONE. 2025;20(4):e0317989. doi:10.1371/journal.pone.0317989

BibTeX
@article{Wahab2025,
  author = {Wahab, Abdul and Asjad, Muhammad Imran and Riaz, Muhammad Bilal and Haider, Jamil Abbas},
  title = {Modeling and simulation of blood flow in unhealthy elliptic arteries with computational fluid dynamics approach},
  journal = {PLOS ONE},
  year = {2025},
  volume = {20},
  number = {4},
  pages = {e0317989},
  doi = {10.1371/journal.pone.0317989}
}
Kostenlos starten →