Biomechanical comparison of various bone reduction forceps in interfragmentary compression and area of compression in an experimental model of canine lateral humeral condylar fractures
PLOS ONE · 2025
DOI: 10.1371/journal.pone.0317793 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift PLOS ONE, 2025. Verfasst von Madison Baskette und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Small Animal Clinical Science, College of Veterinary Medicine, University of Tennessee, Knoxville, Tennessee, United States of America. Hauptthemen laut MEDLINE: Humeral Fractures, Surgical Instruments, Fracture Fixation, Internal, Humerus. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
To compare contact area and interfragmentary compression generated by Vulsellum forceps, Patellar forceps, Kyon FineTouch forceps, point-to-point forceps with soft-locking mechanism, and point-to-point forceps with speed-locking mechanism in simulated lateral humeral condylar fractures in canine cadavers. Study design Ex-vivo biomechanical study. Materials and methods Seven cadaveric canine humeri with simulated lateral humeral condylar fractures were used in this study. A stress-sensitive film was placed at the fracture gap and five different bone reduction forceps were used to reduce the fractures to their maximum pressure before failure occurred. The compression and interfragmentary compression area were recorded during the entire compression interval and compared after the pressure had reached a plateau.
Results
Patellar forceps generated the highest interfragmentary compression, followed by Vulsellum forceps. Compression generated by both the Patellar and Vulsellum forceps were significantly higher than point-to-point forceps with soft-lock, point-to-point forceps with speed lock, and Kyon forceps (P = 0.0008, 0.0084). No statistically significant difference was observed in the areas of compression among all forceps types.
Conclusion
Patellar and Vulsellum forceps generate a greater interfragmentary compression compared to Kyon FineTouch forceps and point-to-point forceps with both speed and soft-locking mechanisms in this experimental lateral condylar fracture model.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Small Animal Clinical Science, College of Veterinary Medicine, University of Tennessee, Knoxville, Tennessee, United States of America.
ORCID-Profile: Madison Baskette
Zitieren
APA
Baskette, M., & Ferrigno, C. R. A. (2025). Biomechanical comparison of various bone reduction forceps in interfragmentary compression and area of compression in an experimental model of canine lateral humeral condylar fractures. PLOS ONE. https://doi.org/10.1371/journal.pone.0317793
Vancouver
Baskette M, Ferrigno CRA. Biomechanical comparison of various bone reduction forceps in interfragmentary compression and area of compression in an experimental model of canine lateral humeral condylar fractures. PLOS ONE. 2025. doi:10.1371/journal.pone.0317793
BibTeX
@article{Baskette2025,
author = {Baskette, Madison and Ferrigno, Cassio Ricardo Auada},
title = {Biomechanical comparison of various bone reduction forceps in interfragmentary compression and area of compression in an experimental model of canine lateral humeral condylar fractures},
journal = {PLOS ONE},
year = {2025},
doi = {10.1371/journal.pone.0317793}
}
EUVIMED