Application of attenuated total reflection–Fourier transform infrared spectroscopy in semi-quantification of blood lipids and characterization of the metabolic syndrome
PLOS ONE · 30.01.2025 · 20 (1) · e0316522
DOI: 10.1371/journal.pone.0316522 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 30.01.2025. Verfasst von Tz-Ping Gau und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan. Hauptthemen laut MEDLINE: Metabolic Syndrome, Lipids. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Health Research Institutes, National Science and Technology Council, Kaohsiung Medical University Chung-Ho Memorial Hospital.
Abstract (Originalsprache)
Background/Purpose Dyslipidemia, a hallmark of metabolic syndrome (MetS), contributes to atherosclerotic and cardiometabolic disorders. Due to days-long analysis, current clinical procedures for cardiotoxic blood lipid monitoring are unmet. This study used AI-assisted attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy to identify MetS and precisely quantify multiple blood lipid levels with a blood sample of 0.5 µl and the assaying time is approximately 10 minutes.
Methods
ATR-FTIR spectroscopy with 1738 data points in the spectral range of 4000–650 cm −1 was used to analyze the blood samples. An adaptive synthetic technique was used to establish a prevalence-balanced dataset. LDL-C, HDL-C, TG, VLDL-C, and cholesterol levels were defined as the predicted targets of lipid absorption profiles. Linear regression (LR), gradient boosting regression tree (GBT), and histogram-based gradient boosting regression tree (HGBTR) were used to train the models. Lipid profile value prediction was evaluated using R 2 and MAE, whereas MetS prediction was evaluated using area under the ROC curve.
Results
A total of 150 blood samples from 25 individuals without MetS and 25 with MetS yielded 491 spectral measurements. In the regression models, HGBT best predicted the targets of TG, CHOL, HDL-C, LDL-C, and VLDL-C with R 2 values of 0.854 (0.12), 0.684 (0.08), 0.758 (0.10), and 0.419 (0.11), respectively. The classification model with the greatest AUC was RF (0.978), followed by HGBT (0.972) and GBT (0.967).
Conclusion
The results of this study revealed that predicting MetS and determining blood lipid levels with high R 2 values and limited errors are feasible for monitoring during therapy and intervention.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Anesthesiology, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan.
- Center for Big Data Research, Kaohsiung Medical University, Kaohsiung, Taiwan.
- Department of Information Management, National Sun Yat-sen University, Kaohsiung, Taiwan.
- School of Medicine, College of Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan.
- Center for General Education, Kaohsiung Medical University, Kaohsiung, Taiwan.
- Group of Life Science, National Synchrotron Radiation Research Center, Hsinchu, Taiwan.
ORCID-Profile: Yao-Chang Lee, Hsiang-Chun Lee
Förderung
- National Health Research Institutes
- National Science and Technology Council
- Kaohsiung Medical University Chung-Ho Memorial Hospital
- Ministry of Science and Technology, Taiwan
Zitieren
APA
Gau, T. P., Wen, J. H., Lu, I. W., Huang, P. Y., Lee, Y. C., Lee, W. P., & Lee, H. C. (2025). Application of attenuated total reflection–Fourier transform infrared spectroscopy in semi-quantification of blood lipids and characterization of the metabolic syndrome. PLOS ONE, 20(1), e0316522. https://doi.org/10.1371/journal.pone.0316522
Vancouver
Gau TP, Wen JH, Lu IW, Huang PY, Lee YC, Lee WP, et al. Application of attenuated total reflection–Fourier transform infrared spectroscopy in semi-quantification of blood lipids and characterization of the metabolic syndrome. PLOS ONE. 2025;20(1):e0316522. doi:10.1371/journal.pone.0316522
BibTeX
@article{Gau2025,
author = {Gau, Tz-Ping and Wen, Jen-Hung and Lu, I-Wei and Huang, Pei-Yu and Lee, Yao-Chang and Lee, Wei-Po and Lee, Hsiang-Chun},
title = {Application of attenuated total reflection–Fourier transform infrared spectroscopy in semi-quantification of blood lipids and characterization of the metabolic syndrome},
journal = {PLOS ONE},
year = {2025},
volume = {20},
number = {1},
pages = {e0316522},
doi = {10.1371/journal.pone.0316522}
}
EUVIMED