EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparison of ocular biometry and refractive outcomes using two swept-source optical coherence tomography-based biometers

Hansol Park, Young-Sik Yoo, Eunhae Shin, Won Seok Song, Yeokyoung Won, Tae-Young Chung, Dong Hui Lim iD

PLOS ONE · 2024

DOI: 10.1371/journal.pone.0316439 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift PLOS ONE, 2024. Verfasst von Hansol Park und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Samsung Medical Center School of Medicine, Sungkyunkwan University, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Biometry, Refraction, Ocular. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Education, Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To evaluate the ocular biometry agreement and prediction of postoperative refractive outcomes obtained using two swept-source optical coherence tomography (SS-OCT) biometers: Anterion (Heidelberg Engineering, Heidelberg, Germany) and Argos (Alcon, Fort Worth, TX, USA).

Methods

Ambispective analysis was conducted on 105 eyes at the Samsung Medical Center, Seoul, Republic of Korea, between June 2021 and March 2022. Biometric values were assessed using both devices before cataract surgery. Intraocular lens (IOL) power, mean arithmetic error (ME), and mean absolute error (MAE) were calculated using the Barrett Universal II, Haigis, and Hoffer Q formulas.

Results

Anterion showed statistically significantly greater axial length (AL), central corneal thickness (CCT), and lens thickness (LT) than Argos (p = 0.03, p < 0.001, and p = 0.032, respectively). There were no significant differences in measuring anterior chamber depth (ACD) (p > 0.05). Anterion showed flatter corneal curvature measurements than Argos (p < 0.001). The postoperative prediction errors differed for all three formulas (p < 0.001). Anterion results leaned towards a slightly myopic outcome due to hyperopic target refraction. In all three formulas, the MAE and percentage of eyes with a prediction error ≤ ± 0.5 D were not significantly different between the two devices.

Conclusion

Although the differences are not clinically significant, the measurements of AL, CCT, and LT obtained with Anterion were greater compared to those measured with Argos, while the keratometry (K) and corneal diameter (CD) values were smaller. Consequently, this resulted in a minor difference in refractive predictability, with Anterion showing a slight tendency toward more myopic refractive errors. However, there were no significant differences in MAE or the percentage of eyes within ± 0.5D.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherenceBiometryRefraction, OcularHumansMaleFemaleMiddle AgedAgedCorneaLenses, IntraocularCataract ExtractionLens, CrystallineLens Implantation, IntraocularAxial Length, Eye

Autor:innen und Institutionen

  • Department of Ophthalmology, Samsung Medical Center School of Medicine, Sungkyunkwan University, Seoul, Republic of Korea.
  • Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
  • Renew Seoul Eye Center, Seoul, Republic of Korea.
  • Samsung Advanced Institute for Health Sciences & Technology, Sungkyunkwan University, Seoul, Republic of Korea.

ORCID-Profile: Dong Hui Lim

Förderung

  • Ministry of Education, Science and Technology

Zitieren

APA

Park, H., Yoo, Y. S., Shin, E., Song, W. S., Won, Y., Chung, T. Y., & Lim, D. H. (2024). Comparison of ocular biometry and refractive outcomes using two swept-source optical coherence tomography-based biometers. PLOS ONE. https://doi.org/10.1371/journal.pone.0316439

Vancouver

Park H, Yoo YS, Shin E, Song WS, Won Y, Chung TY, et al. Comparison of ocular biometry and refractive outcomes using two swept-source optical coherence tomography-based biometers. PLOS ONE. 2024. doi:10.1371/journal.pone.0316439

BibTeX
@article{Park2024,
  author = {Park, Hansol and Yoo, Young-Sik and Shin, Eunhae and Song, Won Seok and Won, Yeokyoung and Chung, Tae-Young and Lim, Dong Hui},
  title = {Comparison of ocular biometry and refractive outcomes using two swept-source optical coherence tomography-based biometers},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0316439}
}
Kostenlos starten →