A drop dispenser for simplifying on-farm detection of foodborne pathogens
PLOS ONE · 31.12.2024 · 19 (12) · e0315444
DOI: 10.1371/journal.pone.0315444 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 31.12.2024. Verfasst von Mohsen Ranjbaran und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, Indiana, United States of America. Hauptthemen laut MEDLINE: Biosensing Techniques, Food Microbiology, Escherichia coli O157. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Center for Produce Safety, California Department of Food and Agriculture, Agricultural Marketing Service.
Abstract (Originalsprache)
Nucleic-acid biosensors have emerged as useful tools for on-farm detection of foodborne pathogens on fresh produce. Such tools are specifically designed to be user-friendly so that a producer can operate them with minimal training and in a few simple steps. However, one challenge in the deployment of these biosensors is delivering precise sample volumes to the biosensor’s reaction sites. To address this challenge, we developed an innovative drop dispenser using advanced 3D printing technology, combined with a hydrophilic surface chemistry treatment. This dispenser enables the generation of precise sample drops, containing DNA or bacterial samples, in volumes as small as a few micro-liters (∼20 to ∼33 μL). The drop generator was tested over an extended period to assess its durability and usability over time. The results indicated that the drop dispensers have a shelf life of approximately one month. In addition, the device was rigorously validated for nucleic acid testing, specifically by using loop-mediated isothermal amplification (LAMP) for the detection of Escherichia coli O157, a prevalent foodborne pathogen. To simulate real-world conditions, we tested the drop dispensers by integrating them into an on-farm sample collection system, ensuring they deliver samples accurately and consistently for nucleic acid testing in the field. Our results demonstrated similar performance to commercial pipettors in LAMP assays, with a limit of detection of 7.8×10 6 cells/mL for whole-cell detection. This combination of precision, ease of use, and durability make our drop dispenser a promising tool for enhancing the effectiveness of nucleic acid biosensors in the field.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, Indiana, United States of America.
- Birck Nanotechnology Center, Purdue University, West Lafayette, Indiana, United States of America.
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, United States of America.
ORCID-Profile: Jiangshan Wang, Mohit S Verma
Förderung
- Center for Produce Safety
- California Department of Food and Agriculture
- Agricultural Marketing Service
Zitieren
APA
Ranjbaran, M., Kaur, S., Wang, J., Raut, B., & Verma, M. S. (2024). A drop dispenser for simplifying on-farm detection of foodborne pathogens. PLOS ONE, 19(12), e0315444. https://doi.org/10.1371/journal.pone.0315444
Vancouver
Ranjbaran M, Kaur S, Wang J, Raut B, Verma MS. A drop dispenser for simplifying on-farm detection of foodborne pathogens. PLOS ONE. 2024;19(12):e0315444. doi:10.1371/journal.pone.0315444
BibTeX
@article{Ranjbaran2024,
author = {Ranjbaran, Mohsen and Kaur, Simerdeep and Wang, Jiangshan and Raut, Bibek and Verma, Mohit S},
title = {A drop dispenser for simplifying on-farm detection of foodborne pathogens},
journal = {PLOS ONE},
year = {2024},
volume = {19},
number = {12},
pages = {e0315444},
doi = {10.1371/journal.pone.0315444}
}
EUVIMED