External negative pressure transiently reduces intravenous pressure and augments the arteriovenous pressure gradient in the affected limb segment
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0315231 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Nigel A Callender und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, University of Oslo, Oslo, Norway. Hauptthemen laut MEDLINE: Blood Pressure. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Norges Forskningsråd.
Abstract (Originalsprache)
Recently intermittent negative pressure has emerged as a potential treatment in vascular disease and has similarities with established experimental interventions such as lower body negative pressure. The direct, local influences of either method upon intravascular pressure still require some clarification however, particularly in the immediate moments following onset. We investigated the acute intravascular pressure responses to intermittent cycles of negative pressure in the supine and sitting postures. Fifteen participants (6 female) received intermittent negative pressure cycles (-37 mmHg; 9.5-sec on, 7.5-sec off) upon the lower leg in both postures. Saphenous venous ( n = 15), and dorsalis pedis artery pressure ( n = 3) were recorded via pressure catheter, alongside beat-by-beat systemic cardiovascular parameters (heart rate and blood pressure; n = 15), from which the arteriovenous pressure gradient was ultimately derived. Negative pressure induced a transient reduction in local intravenous pressure (Supine: 14±3 mmHg to -18±6 mmHg, p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Faculty of Medicine, University of Oslo, Oslo, Norway.
- Department of Vascular Surgery, Oslo University Hospital, Oslo, Norway.
- Otivio AS, Oslo, Norway.
- Department of Anaesthesia and Intensive Care, Oslo University Hospital, Oslo, Norway.
ORCID-Profile: Nigel A Callender, Jonny Hisdal
Förderung
- Norges Forskningsråd
Zitieren
APA
Callender, N. A., Høiseth, L. Ø., & Hisdal, J. (2024). External negative pressure transiently reduces intravenous pressure and augments the arteriovenous pressure gradient in the affected limb segment. PLOS ONE. https://doi.org/10.1371/journal.pone.0315231
Vancouver
Callender NA, Høiseth LØ, Hisdal J. External negative pressure transiently reduces intravenous pressure and augments the arteriovenous pressure gradient in the affected limb segment. PLOS ONE. 2024. doi:10.1371/journal.pone.0315231
BibTeX
@article{Callender2024,
author = {Callender, Nigel A and Høiseth, Lars Øivind and Hisdal, Jonny},
title = {External negative pressure transiently reduces intravenous pressure and augments the arteriovenous pressure gradient in the affected limb segment},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0315231}
}