EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Inter-rater reliability in labeling quality and pathological features of retinal OCT scans: A customized annotation software approach

Katherine Du, Stavan Shah, Sandeep Chandra Bollepalli iD, Mohammed Nasar Ibrahim iD, Adarsh Gadari, Shan Sutharahan, José-Alain Sahel, Jay Chhablani, Kiran Kumar Vupparaboina iD

PLOS ONE · 2024

DOI: 10.1371/journal.pone.0314707 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Katherine Du und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, University of Pittsburgh Medical Center, Pittsburgh, PA, United States of America. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Software, Retina. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NEI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Various imaging features on optical coherence tomography (OCT) are crucial for identifying and defining disease progression. Establishing a consensus on these imaging features is essential, particularly for training deep learning models for disease classification. This study aims to analyze the inter-rater reliability in labeling the quality and common imaging signatures of retinal OCT scans.

Methods

500 OCT scans obtained from CIRRUS HD-OCT 5000 devices were displayed at 512x1024x128 resolution on a customizable, in-house annotation software. Each patient’s eye was represented by 16 random scans. Two masked reviewers independently labeled the quality and specific pathological features of each scan. Evaluated features included overall image quality, presence of fovea, and disease signatures including subretinal fluid (SRF), intraretinal fluid (IRF), drusen, pigment epithelial detachment (PED), and hyperreflective material. The raw percentage agreement and Cohen’s kappa (κ) coefficient were used to evaluate concurrence between the two sets of labels.

Results

Our analysis revealed κ = 0.60 for the inter-rater reliability of overall scan quality, indicating substantial agreement. In contrast, there was slight agreement in determining the cause of poor image quality (κ = 0.18). The binary determination of presence and absence of retinal disease signatures showed almost complete agreement between reviewers (κ = 0.85). Specific retinal pathologies, such as the foveal location of the scan (0.78), IRF (0.63), drusen (0.73), and PED (0.87), exhibited substantial concordance. However, less agreement was found in identifying SRF (0.52), hyperreflective dots (0.41), and hyperreflective foci (0.33).

Conclusions

Our study demonstrates significant inter-rater reliability in labeling the quality and retinal pathologies on OCT scans. While some features show stronger agreement than others, these standardized labels can be utilized to create automated machine learning tools for diagnosing retinal diseases and capturing valuable pathological features in each scan. This standardization will aid in the consistency of medical diagnoses and enhance the accessibility of OCT diagnostic tools.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherenceSoftwareRetinaHumansReproducibility of ResultsRetinal DiseasesObserver VariationMaleFemaleImage Processing, Computer-AssistedDeep Learning

Autor:innen und Institutionen

  • Department of Ophthalmology, University of Pittsburgh Medical Center, Pittsburgh, PA, United States of America.
  • Department of Computer Science, University of North Carolina at Greensboro, Greensboro, NC, United States of America.

ORCID-Profile: Sandeep Chandra Bollepalli, Mohammed Nasar Ibrahim, Kiran Kumar Vupparaboina

Förderung

  • NEI NIH HHS

Zitieren

APA

Du, K., Shah, S., Bollepalli, S. C., Ibrahim, M. N., Gadari, A., Sutharahan, S., Sahel, J. A., Chhablani, J., & Vupparaboina, K. K. (2024). Inter-rater reliability in labeling quality and pathological features of retinal OCT scans: A customized annotation software approach. PLOS ONE. https://doi.org/10.1371/journal.pone.0314707

Vancouver

Du K, Shah S, Bollepalli SC, Ibrahim MN, Gadari A, Sutharahan S, et al. Inter-rater reliability in labeling quality and pathological features of retinal OCT scans: A customized annotation software approach. PLOS ONE. 2024. doi:10.1371/journal.pone.0314707

BibTeX
@article{Du2024,
  author = {Du, Katherine and Shah, Stavan and Bollepalli, Sandeep Chandra and Ibrahim, Mohammed Nasar and Gadari, Adarsh and Sutharahan, Shan and Sahel, José-Alain and Chhablani, Jay and Vupparaboina, Kiran Kumar},
  title = {Inter-rater reliability in labeling quality and pathological features of retinal OCT scans: A customized annotation software approach},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0314707}
}
Kostenlos starten →