EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access · CC BY 4.0

The impact of a commercial lower extremity exoskeleton on metabolic load, perceived exertion, and physiological response to a challenging military relevant task: A randomized cross-over design pilot study

JoEllen M Sefton iD, Frances K Neal, Philip J Agostinelli, Nicholas C Bordonie, Phillip E Whitley, Nathan T Pickle iD, Paulien E Roos iD

PLOS ONE · 2025

DOI: 10.1371/journal.pone.0314613 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift PLOS ONE, 2025. Verfasst von JoEllen M Sefton und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Kinesiology, Auburn University, Auburn, AL, United States of America. Hauptthemen laut MEDLINE: Exoskeleton Device, Physical Exertion, Lower Extremity. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIEHS NIH HHS, United States Army Futures Command.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To assess physiological metrics during the use of a commercially available bilateral active ankle exoskeleton during a challenging military-relevant task and if use of the exoskeleton during this task influences: metabolic load, physiological measures or rate of perceived exertion.

Methods

Nine healthy volunteers (5M, 4F) completed this randomized cross-over design trial, with a baseline visit and two randomized test sessions (with/without the exoskeleton). Variables included impact on time to exhaustion during walking on a treadmill at varying speeds and gradients (0–15%) at 26.7°C, 50% humidity with a loaded rucksack (30% body weight). The primary outcome measure was change in metabolic cost with/without the exoskeleton (O2 consumption, metabolic equivalents); secondary outcomes were change in heart rate and perceived exertion between conditions.

Results

Participants averaged 22.4 ± 4.5 years old, 173.7 ± 7.4 cm tall, weighed 80.9 ± 13.9 kg, and VO 2 max of 43.8 ± 10.6 mL/kg/min. Total kcals did not differ between conditions (with/without exoskeleton; t = 0.98; p = 0.357). Kcals/min were significantly lower (1.06 kcals/min) with the exoskeleton (t = 3.94; p = 0.004). Average oxygen consumption (VO2) was significantly lower (2.36 mL/kg/min) with the exoskeleton (t = 2.81; p = 0.023), and peak VO2 was 3.33 mL/kg/min lower with the exoskeleton (t = 2.37; p = 0.045). Peak and Average METS were also lower with the exoskeleton by 0.98 (t = 2.61; p = 0.031) and 1.23 (t = 2.39; p = 0.044) respectively.

Conclusions

Results suggest a powered ankle exoskeleton may decrease energy consumption during military relevant tasks when conducted in a laboratory environment. There may also be physiological benefits such as reduced core temperate and heart rate. Replication of this work in the field environment is warranted.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Exoskeleton DevicePhysical ExertionLower ExtremityHumansMaleCross-Over StudiesFemaleOxygen ConsumptionYoung AdultAdultHeart RatePilot ProjectsMilitary PersonnelEnergy MetabolismWalkingExercise Test

Autor:innen und Institutionen

  • School of Kinesiology, Auburn University, Auburn, AL, United States of America.
  • CFD Research Corporation, Huntsville, AL, United States of America.

ORCID-Profile: JoEllen M Sefton, Nathan T Pickle, Paulien E Roos

Förderung

  • NIEHS NIH HHS
  • United States Army Futures Command

Zitieren

APA

Sefton, J. M., Neal, F. K., Agostinelli, P. J., Bordonie, N. C., Whitley, P. E., Pickle, N. T., & Roos, P. E. (2025). The impact of a commercial lower extremity exoskeleton on metabolic load, perceived exertion, and physiological response to a challenging military relevant task: A randomized cross-over design pilot study. PLOS ONE. https://doi.org/10.1371/journal.pone.0314613

Vancouver

Sefton JM, Neal FK, Agostinelli PJ, Bordonie NC, Whitley PE, Pickle NT, et al. The impact of a commercial lower extremity exoskeleton on metabolic load, perceived exertion, and physiological response to a challenging military relevant task: A randomized cross-over design pilot study. PLOS ONE. 2025. doi:10.1371/journal.pone.0314613

BibTeX
@article{Sefton2025,
  author = {Sefton, JoEllen M and Neal, Frances K and Agostinelli, Philip J and Bordonie, Nicholas C and Whitley, Phillip E and Pickle, Nathan T and Roos, Paulien E},
  title = {The impact of a commercial lower extremity exoskeleton on metabolic load, perceived exertion, and physiological response to a challenging military relevant task: A randomized cross-over design pilot study},
  journal = {PLOS ONE},
  year = {2025},
  doi = {10.1371/journal.pone.0314613}
}
Kostenlos starten →