EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The test-retest reliability of the H-Reflex and swaymeter in women aged 30–65 years

Rosiered Brownson-Smith iD, Jack Carr iD, Kai T Fox, Samuel T Orange, Nicola Cresti, John Saxton, John Temesi

PLOS One · 2025

DOI: 10.1371/journal.pone.0314437 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, 2025. Verfasst von Rosiered Brownson-Smith und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nutritional Sciences, Faculty of Life Sciences & Medicine, King's College London. Hauptthemen laut MEDLINE: H-Reflex, Postural Balance. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The H-reflex can objectively assess sensorimotor integration relevant to proprioception and postural control. Chemotherapy-induced peripheral neuropathy (CIPN) is a common and potentially dose-limiting side effect among breast cancer patients undergoing taxane-based treatments, leading to proprioception loss and balance issues, and an increased risk of falling. This study evaluated the between-day test-retest reliability of neurophysiological measures and postural sway, measured via swaymeter in a demographically similar population to those affected by breast cancer.

Methods

25 women aged 30–65 years were assessed on two occasions, approximately two weeks apart. The study measured between-day test-retest reliability of the soleus H-reflex and M-wave and postural sway, measured by the swaymeter.

Results

The soleus maximum H-reflex amplitude (H max ) and maximum M-wave amplitude (M max ) exhibited good to excellent (ICC = 0.92, 95% CI: 0.82–0.96) and moderate to excellent (ICC = 0.81, 95% CI: 0.62–0.91) between-day reliability, respectively. The H max /M max showed poor to good between-day reliability (ICC = 0.63, 95% CI: 0.31–0.82), and H-reflex latency demonstrated moderate to excellent between-day reliability (ICC = 0.83, 95% CI: 0.65–0.92). The between-day test-retest reliability of anteroposterior (AP) displacement and total sway across the two testing sessions was poor to moderate (ICC = 0.37, 95% CI: −0.03–0.66 and ICC = 0.42, 95% CI: 0.04–0.70, respectively).

Conclusions

H-reflex and M-wave measures are reliable for between-day assessments. However, sway measures via swaymeter were less reliable, indicating a need for more robust tools to evaluate balance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

H-ReflexPostural BalanceHumansFemaleMiddle AgedAdultAgedReproducibility of ResultsElectromyographyBreast NeoplasmsPeripheral Nervous System DiseasesProprioceptionMuscle, Skeletal

Autor:innen und Institutionen

  • Department of Nutritional Sciences, Faculty of Life Sciences & Medicine, King's College London.
  • Department of Sport, Exercise and Rehabilitation, Faculty of Health and Life Sciences, Northumbria University, Newcastle-upon-Tyne, United Kingdom.
  • Research Centre for Physical Activity, Sport and Exercise Sciences, Coventry University, Coventry, United Kingdom.
  • School of Biomedical, Nutritional and Sport Sciences, Faculty of Medical Sciences, Newcastle University, Newcastle-upon-Tyne, United Kingdom.
  • Newcastle University Centre for Cancer, Newcastle University, Newcastle-upon-Tyne, United Kingdom.
  • Northern Centre for Cancer Care, The Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle-upon-Tyne, United Kingdom.

ORCID-Profile: Rosiered Brownson-Smith, Jack Carr

Zitieren

APA

Brownson-Smith, R., Carr, J., Fox, K. T., Orange, S. T., Cresti, N., Saxton, J., & Temesi, J. (2025). The test-retest reliability of the H-Reflex and swaymeter in women aged 30–65 years. PLOS One. https://doi.org/10.1371/journal.pone.0314437

Vancouver

Brownson-Smith R, Carr J, Fox KT, Orange ST, Cresti N, Saxton J, et al. The test-retest reliability of the H-Reflex and swaymeter in women aged 30–65 years. PLOS One. 2025. doi:10.1371/journal.pone.0314437

BibTeX
@article{BrownsonSmith2025,
  author = {Brownson-Smith, Rosiered and Carr, Jack and Fox, Kai T and Orange, Samuel T and Cresti, Nicola and Saxton, John and Temesi, John},
  title = {The test-retest reliability of the H-Reflex and swaymeter in women aged 30–65 years},
  journal = {PLOS One},
  year = {2025},
  doi = {10.1371/journal.pone.0314437}
}
Kostenlos starten →