Assessment of the hazard risks on HVDC transmission networks due to lightning strikes and faults

Abdelrahman Said, Mohamed Galal iD, M A Abd-Allah

PLOS ONE · 2024

DOI: 10.1371/journal.pone.0313229 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Abdelrahman Said und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, Faculty of Engineering at Shoubra, Benha University, Cairo, Egypt. Hauptthemen laut MEDLINE: Lightning. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

HVDC systems with high voltage and direct current are suitable for reducing electricity losses, during transmission over long distances. However, HVDC lines have the highest probability of failure within a system and can be damaged by different faults or lightning strikes. This paper presents a transient circuit model for the practical Egypt–Saudi Arabia link. The transient potential at different points along the line is calculated under different magnitudes and shapes of lightning strokes. "Additionally, the extent of transient overvoltages at the rectifier station due to shifts in lightning strike locations has been estimated. Furthermore, overvoltage distributions are examined caused by lightning strikes on a real ± 500 kV hybrid HVDC TL-Cableare examined. To prevent national disasters and maintain safe national ratios of electrical production, particularly in the case of hybrid HVDC TL-Cable faults, an analysis of different AC/DC faults in the hybrid HVDC TL-Cable is also presented. This study is based on an equivalent electrical model using Power Systems Computer-Aided Design (PSCAD) software. It was discovered that severe voltages appear at the rectifier station when 50 kAlightning stroke with 1.2 μ sec front time, and 350 μ sectail time hits the TL. Moreover, overvoltages are reduced by about 58% in hybrid HVDC TL-Cable. Also, surge arresters at rectifier stations reduce overvoltages by approximately 95%. Ultimately, DC pole-to-ground faults are more serious than other types of faults and can cause massive overcurrent in the system, potentially damaging the rectifier station.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LightningHumansElectricityElectric Power SuppliesModels, TheoreticalEgyptRisk AssessmentEquipment Failure

Autor:innen und Institutionen

  • Department of Electrical Engineering, Faculty of Engineering at Shoubra, Benha University, Cairo, Egypt.
  • Faculty of Computer Science, Benha National University (BNU), Al Obour, Egypt.

ORCID-Profile: Mohamed Galal

Zitieren

APA

Said, A., Galal, M., & Abd-Allah, M. A. (2024). Assessment of the hazard risks on HVDC transmission networks due to lightning strikes and faults. PLOS ONE. https://doi.org/10.1371/journal.pone.0313229

Vancouver

Said A, Galal M, Abd-Allah MA. Assessment of the hazard risks on HVDC transmission networks due to lightning strikes and faults. PLOS ONE. 2024. doi:10.1371/journal.pone.0313229

BibTeX
@article{Said2024,
  author = {Said, Abdelrahman and Galal, Mohamed and Abd-Allah, M A},
  title = {Assessment of the hazard risks on HVDC transmission networks due to lightning strikes and faults},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0313229}
}
Kostenlos starten →