EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

UV-C disinfection of ultrasound probes: Challenges of uneven irradiance on complex surfaces

LaReine Yeoh, Luke Cogar, Mayes Barak, Lit Yeen Tan, Gavin Spargo, Jon Burdach iD

PLOS ONE · 30.10.2024 · 19 (10) · e0312931

DOI: 10.1371/journal.pone.0312931 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 30.10.2024. Verfasst von LaReine Yeoh und 5 weiteren Autor:innen. Beteiligte Einrichtung: Technology Development Group, Nanosonics Ltd., Sydney, Australia. Hauptthemen laut MEDLINE: Ultraviolet Rays, Disinfection. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nanosonics Ltd.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Medical devices that contact non-intact skin or mucous membranes are considered semi-critical devices and must undergo high-level disinfection (HLD) before use. Studies have identified several potential limitations of UV-C for HLD of semi-critical medical devices, including a lack of data demonstrating that UV-C irradiance can be uniformly applied to complex surfaces that contain grooves, notches and imperfections. This study focused on ultrasound probes as commonly used medical devices to show the distribution of irradiance on these surfaces. An endocavity bi-plane probe and curved array surface probe with typical surface topology were 3D scanned and modelled and an array of UV-C light-emitting diodes (LEDs) irradiating the probe surfaces was simulated (simulated wavelength: 275nm [peak], power output: 50mW). The simulated chamber wall material was equivalent to highly reflective polished aluminum with a defined reflectance of 79% at 275nm. To calculate the cycle time required to achieve HLD on probe surfaces, a minimum effective dosage of 1500mJ/cm 2 based on published research was used. The simulated irradiance distribution showed a large difference between the points of highest and lowest irradiance (maximum/minimum ratio: 14.70 for the surface probe and 12.74 for the endocavity probe). In addition, the presence of shadowing effects adjacent to notches or grooves was evident. By applying an effective UV-C dose from the literature, cycle times of up to 25 minutes would be required to achieve HLD in the minimally irradiated areas of the probes used in the simulation. These findings highlight the need to demonstrate the efficacy of UV-C radiation against worst case organisms in the areas of lowest irradiance on medical devices to provide assurance these devices are reliably high level disinfected.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ultraviolet RaysDisinfectionUltrasonographySurface PropertiesHumans

Autor:innen und Institutionen

  • Technology Development Group, Nanosonics Ltd., Sydney, Australia.
  • Bioscience, Nanosonics Ltd., Sydney, Australia.
  • Clinical Affairs, Nanosonics Ltd., Sydney, Australia.
  • Medical Affairs, Nanosonics Ltd., Sydney, Australia.

ORCID-Profile: Jon Burdach

Förderung

  • Nanosonics Ltd

Zitieren

APA

Yeoh, L., Cogar, L., Barak, M., Tan, L. Y., Spargo, G., & Burdach, J. (2024). UV-C disinfection of ultrasound probes: Challenges of uneven irradiance on complex surfaces. PLOS ONE, 19(10), e0312931. https://doi.org/10.1371/journal.pone.0312931

Vancouver

Yeoh L, Cogar L, Barak M, Tan LY, Spargo G, Burdach J. UV-C disinfection of ultrasound probes: Challenges of uneven irradiance on complex surfaces. PLOS ONE. 2024;19(10):e0312931. doi:10.1371/journal.pone.0312931

BibTeX
@article{Yeoh2024,
  author = {Yeoh, LaReine and Cogar, Luke and Barak, Mayes and Tan, Lit Yeen and Spargo, Gavin and Burdach, Jon},
  title = {UV-C disinfection of ultrasound probes: Challenges of uneven irradiance on complex surfaces},
  journal = {PLOS ONE},
  year = {2024},
  volume = {19},
  number = {10},
  pages = {e0312931},
  doi = {10.1371/journal.pone.0312931}
}