EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Nitrile glove composition and performance—Substandard properties and inaccurate packaging information

Ashley Herkins iD, Sriloy Dey, Dan Conroy, Katrina Cornish iD

PLOS ONE · 2024

DOI: 10.1371/journal.pone.0312891 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Ashley Herkins und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Food, Agricultural, and Biological Engineering, The Ohio State University, Columbus, Ohio, United States of America. Hauptthemen laut MEDLINE: Nitriles. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institute of Food and Agriculture.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The durability and mechanical properties of synthetic medical gloves, such as those made from nitrile, vary drastically depending on the manufacturer. This study reports the chemical composition of several brands of nitrile gloves via FTIR and solid-state NMR analysis and relates composition to glove durability (found via GAD), mechanical performance (found via Instron), and whether the gloves meet or fail ASTM International standards. Out of the four nitrile examination glove brands tested, American Nitrile Slate brand had superior durability results and was found to be made of acrylonitrile butadiene rubber, as expected. The U.S. Medical glove brand, which was also found to be pure nitrile, had the superior tensile results, consistently reaching over 800% elongation before breaking. Although Restore Touch brand exam gloves were made of nitrile, they exhibited substandard tensile strength and durability due to the thinness of the glove, which barely met the ASTM minimum thickness value. The Vglove brand glove had the overall worst mechanical properties, did not meet ASTM requirements, and had an NMR spectrum consistent with that of a polyvinyl chloride glove, rather than nitrile. Gloves that fail to meet the minimum performance requirements should not be used for medical purposes to protect the health and safety of consumers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NitrilesTensile StrengthMaterials TestingGloves, ProtectiveProduct PackagingGloves, SurgicalSpectroscopy, Fourier Transform InfraredMagnetic Resonance SpectroscopyHumans

Substanzen

Nitriles

Autor:innen und Institutionen

  • Department of Food, Agricultural, and Biological Engineering, The Ohio State University, Columbus, Ohio, United States of America.
  • Department of Food Science and Technology, The Ohio State University, Columbus, Ohio, United States of America.
  • Department of Chemistry and Biochemistry, The Ohio State University, Columbus, Ohio, United States of America.
  • Department of Horticulture and Crop Science, The Ohio State University, Columbus, Ohio, United States of America.
  • EnergyEne Inc., Wooster, Ohio, United States of America.

ORCID-Profile: Ashley Herkins, Katrina Cornish

Förderung

  • National Institute of Food and Agriculture

Zitieren

APA

Herkins, A., Dey, S., Conroy, D., & Cornish, K. (2024). Nitrile glove composition and performance—Substandard properties and inaccurate packaging information. PLOS ONE. https://doi.org/10.1371/journal.pone.0312891

Vancouver

Herkins A, Dey S, Conroy D, Cornish K. Nitrile glove composition and performance—Substandard properties and inaccurate packaging information. PLOS ONE. 2024. doi:10.1371/journal.pone.0312891

BibTeX
@article{Herkins2024,
  author = {Herkins, Ashley and Dey, Sriloy and Conroy, Dan and Cornish, Katrina},
  title = {Nitrile glove composition and performance—Substandard properties and inaccurate packaging information},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0312891}
}