Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Dominic Michael Rasp und 3 weiteren Autor:innen. Beteiligte Einrichtung: Biomechanics in Sports, Technical University of Munich, Munich, Bavaria, Germany. Hauptthemen laut MEDLINE: Muscle Strength, Hamstring Muscles, Isometric Contraction. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Hamstring injuries are associated with decreased hamstring strength. Matinlauri et al.’s 90:20 Isometric Posterior Chain Test (90:20 IPCT) efficiently assesses hamstring strength, but has not been validated so far. Furthermore, their rather unprecise original instruction allows high variability in test execution. We added a new instruction and variables and examined, whether this measure leads to increased reliability and validity. We assessed hamstring strength of 23 sport students via the 90:20 IPCT under the original instruction, to exert vertical force, and our new instruction, to exert vertical and horizontal force. Instead of only using bare vertical force as variable under the original (Fz_V) and our new instruction (Fz_VH), we also calculated the resultant force (Fres_VH) and the applied torque onto the force place (M_F_ortho_VH). To test for validity, we correlated the outcome variables with peak torque of gold standard dynamometry. Furthermore, we measured muscle activities of the mm. rectus femoris, biceps femoris, semitendinosus, and gluteus maximus under our new instruction and compared them to those under the original variable (Fz_V) via one sample t-tests. To evaluate reliability, tests were repeated on two separate days, for which we calculated intra class correlation coefficients (ICCs) and coefficients of variation (CVs). Our new instruction and variables (Fz_VH, Fres_VH, M_F_ortho_VH) showed better validity (mean r = 0.77, r = 0.81, and r = 0.85) and equally good or better reliability (ICCs: 0.87, 0.89, and 0.94; CVs: 4.7%, 4.1%, and 4.7%) than the original instruction and variable (Fz_V) (mean r = 0.70; ICC: 0.91; CV: 5.6%). There were no differences in muscle activities between the variables and instructions of the 90:20 IPCT. We recommend our new instruction and the applied torque onto the force plate as it makes the 90:20 IPCT a more reliable and valid tool to assess hamstring strength.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Biomechanics in Sports, Technical University of Munich, Munich, Bavaria, Germany.
- Human Movement Science, Technical University of Munich, Munich, Bavaria, Germany.
ORCID-Profile: Dominic Michael Rasp, Florian Kurt Paternoster
Zitieren
APA
Rasp, D. M., Paternoster, F. K., Kern, J., & Schwirtz, A. (2024). Precise instruction and consideration of the vertical and horizontal force component increases validity and reliability of the 90:20 Isometric Posterior Chain Test. PLOS ONE. https://doi.org/10.1371/journal.pone.0312843
Vancouver
Rasp DM, Paternoster FK, Kern J, Schwirtz A. Precise instruction and consideration of the vertical and horizontal force component increases validity and reliability of the 90:20 Isometric Posterior Chain Test. PLOS ONE. 2024. doi:10.1371/journal.pone.0312843
BibTeX
@article{Rasp2024,
author = {Rasp, Dominic Michael and Paternoster, Florian Kurt and Kern, Jan and Schwirtz, Ansgar},
title = {Precise instruction and consideration of the vertical and horizontal force component increases validity and reliability of the 90:20 Isometric Posterior Chain Test},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0312843}
}
EUVIMED