EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Artificial intelligence applied in identifying left ventricular walls in myocardial perfusion scintigraphy images: Pilot study

Solange Amorim Nogueira iD, Fernanda Ambrogi B Luz, Thiago Fellipe O Camargo, Julio Cesar S Oliveira, Guilherme Carvalho Campos Neto, Felipe Brazao F Carvalhaes, Marcio Rodrigues C Reis, Paulo Victor Santos, Giovanna Souza Mendes, Rafael Maffei Loureiro iD, Daniel Tornieri, Viviane M Gomes Pacheco und 2 weitere

PLOS ONE · 2025

DOI: 10.1371/journal.pone.0312257 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2025. Verfasst von Solange Amorim Nogueira und 13 weiteren Autor:innen. Beteiligte Einrichtung: Electrical, Mechanical & Computer Engineering School, Federal University of Goias, Goiania, Brazil. Hauptthemen laut MEDLINE: Myocardial Perfusion Imaging, Heart Ventricles, Artificial Intelligence, Coronary Artery Disease. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 74 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Institutional Development Support Program of the Unified Health System, Fundação para a Ciência e a Tecnologia, I.P., National Council for Scientific and Technological Development.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper proposes the use of artificial intelligence techniques, specifically the nnU-Net convolutional neural network, to improve the identification of left ventricular walls in images of myocardial perfusion scintigraphy, with the objective of improving the diagnosis and treatment of coronary artery disease. The methodology included data collection in a clinical environment, followed by data preparation and analysis using the 3D Slicer Platform for manual segmentation, and subsequently, the application of artificial intelligence models for automated segmentation, focusing on the efficiency of identifying the walls of the left ventricular. A total of 83 clinical routine exams were collected, each exam containing 50 slices, which is 4,150 images. The results demonstrate the efficiency of the proposed artificial intelligence model, with a Dice coefficient of 87% and an average Intersection over Union of 0.8, reflecting high agreement with the manual segmentations produced by experts and surpassing traditional interpretation methods. The internal and external validation of the model corroborates its future applicability in real clinical scenarios, offering a new perspective in the analysis of myocardial perfusion scintigraphy images. The integration of artificial intelligence into the process of analyzing myocardial perfusion scintigraphy images represents a significant advancement in diagnostic accuracy, promoting substantial improvements in the interpretation of medical images, and establishing a foundation for future research and clinical applications, such as artifact correction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Myocardial Perfusion ImagingHeart VentriclesArtificial IntelligenceCoronary Artery DiseaseHumansPilot ProjectsNeural Networks, ComputerFemaleMaleMiddle AgedAged

Autor:innen und Institutionen

  • Electrical, Mechanical & Computer Engineering School, Federal University of Goias, Goiania, Brazil.
  • Hospital Israelita Albert Einstein, Sao Paulo, Brazil.
  • Technology Research and Development Center (GCITE), Federal Institute of Goias, Goiania, Goias, Brazil.
  • Systems and Robotics Institute, Coimbra University, Coimbra, Portugal.

ORCID-Profile: Solange Amorim Nogueira, Rafael Maffei Loureiro, Wesley Pacheco Calixto

Förderung

  • Institutional Development Support Program of the Unified Health System
  • Fundação para a Ciência e a Tecnologia, I.P.
  • National Council for Scientific and Technological Development
  • Goiás State Research Support Foundation

Zitieren

APA

Nogueira, S. A., Luz, F. A. B., Camargo, T. F. O., Oliveira, J. C. S., Campos Neto, G. C., Carvalhaes, F. B. F., Reis, M. R. C., Santos, P. V., Mendes, G. S., Loureiro, R. M., Tornieri, D., Pacheco, V. M. G., Coimbra, A. P., & Calixto, W. P. (2025). Artificial intelligence applied in identifying left ventricular walls in myocardial perfusion scintigraphy images: Pilot study. PLOS ONE. https://doi.org/10.1371/journal.pone.0312257

Vancouver

Nogueira SA, Luz FAB, Camargo TFO, Oliveira JCS, Campos Neto GC, Carvalhaes FBF, et al. Artificial intelligence applied in identifying left ventricular walls in myocardial perfusion scintigraphy images: Pilot study. PLOS ONE. 2025. doi:10.1371/journal.pone.0312257

BibTeX
@article{Nogueira2025,
  author = {Nogueira, Solange Amorim and Luz, Fernanda Ambrogi B and Camargo, Thiago Fellipe O and Oliveira, Julio Cesar S and Campos Neto, Guilherme Carvalho and Carvalhaes, Felipe Brazao F and Reis, Marcio Rodrigues C and Santos, Paulo Victor and Mendes, Giovanna Souza and Loureiro, Rafael Maffei and Tornieri, Daniel and Pacheco, Viviane M Gomes and Coimbra, Antonio Paulo and Calixto, Wesley Pacheco},
  title = {Artificial intelligence applied in identifying left ventricular walls in myocardial perfusion scintigraphy images: Pilot study},
  journal = {PLOS ONE},
  year = {2025},
  doi = {10.1371/journal.pone.0312257}
}
Kostenlos starten →