EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An exploratory study of the impact of CT slice thickness and inter-rater variability on anatomical accuracy of malunited distal radius models and surgical guides for corrective osteotomy

Emilia Gryska iD, Per Fredrikson, Katleen Libberecht, Charlotte Stor Swinkels, Peter Axelsson, Anders Björkman

PLOS ONE · 10.10.2024 · 19 (10) · e0311805

DOI: 10.1371/journal.pone.0311805 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 10.10.2024. Verfasst von Emilia Gryska und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hand Surgery, Sahlgrenska University Hospital, Mölndal, Sweden. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Osteotomy, Radius. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ALF-agreement.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-resolution CT images are essential in clinical practice to accurately replicate patient anatomy for 3D virtual surgical planning and designing patient-specific surgical guides. These technologies are commonly used in corrective osteotomy of the distal radius. This study evaluated how the virtual radius models and the surgical guides’ surface that is in contact with the bone vary between experienced raters. Further, the discrepancies from the reference radius of surgical guides and radius models created from CT images with slice thicknesses larger than the reference standard of 0.625mm were assessed. Maximum overlap with radius model was measured for guides, and absolute average distance error was measured for radius models. The agreement between the lower-resolution guides surface and the raters’ guide surface was evaluated. The average inter-rater guide surface overlap was -0.11mm [95% CI: -0.13–0.09]. The surface of surgical guides designed on CT images with a 1mm slice thickness deviated from the reference radius within the inter-rater range (0.03mm). For slice thicknesses of 1.25mm and 1.5mm, the average guide surface overlap was 0.12mm and 0.15mm, respectively. The average inter-rater radius surface variability was 0.03mm [95% CI: 0.025–0.035]. The discrepancy from the reference of all radius models created from CT images with a slice thickness larger than the reference slice thickness was notably larger than the inter-rater variability but, excluding one case, did not exceed 0.2mm. The results suggest that 1mm CT images are suitable for surgical guide design. While 1.25mm slices are commonly used for virtual planning in hand and forearm surgery, slices larger than 1mm may approach the limit of clinical acceptability. Discrepancies in radius models were below 1mm, likely below clinical relevance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedOsteotomyRadiusHumansObserver VariationMaleFemaleSurgery, Computer-AssistedModels, AnatomicImaging, Three-DimensionalAdultFractures, Malunited

Autor:innen und Institutionen

  • Department of Hand Surgery, Sahlgrenska University Hospital, Mölndal, Sweden.
  • Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
  • Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden.

ORCID-Profile: Emilia Gryska

Förderung

  • ALF-agreement

Zitieren

APA

Gryska, E., Fredrikson, P., Libberecht, K., Stor Swinkels, C., Axelsson, P., & Björkman, A. (2024). An exploratory study of the impact of CT slice thickness and inter-rater variability on anatomical accuracy of malunited distal radius models and surgical guides for corrective osteotomy. PLOS ONE, 19(10), e0311805. https://doi.org/10.1371/journal.pone.0311805

Vancouver

Gryska E, Fredrikson P, Libberecht K, Stor Swinkels C, Axelsson P, Björkman A. An exploratory study of the impact of CT slice thickness and inter-rater variability on anatomical accuracy of malunited distal radius models and surgical guides for corrective osteotomy. PLOS ONE. 2024;19(10):e0311805. doi:10.1371/journal.pone.0311805

BibTeX
@article{Gryska2024,
  author = {Gryska, Emilia and Fredrikson, Per and Libberecht, Katleen and Stor Swinkels, Charlotte and Axelsson, Peter and Björkman, Anders},
  title = {An exploratory study of the impact of CT slice thickness and inter-rater variability on anatomical accuracy of malunited distal radius models and surgical guides for corrective osteotomy},
  journal = {PLOS ONE},
  year = {2024},
  volume = {19},
  number = {10},
  pages = {e0311805},
  doi = {10.1371/journal.pone.0311805}
}
Kostenlos starten →