Glomerular filtration rate determined by measuring serum clearance of iohexol in unanesthetized cheetahs (Acinonyx jubatus) with comparison to serum symmetric dimethylarginine
PLOS ONE · 01.10.2024 · 19 (10) · e0311406
DOI: 10.1371/journal.pone.0311406 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift PLOS ONE, online erschienen am 01.10.2024. Verfasst von Nicholas Lordi und 2 weiteren Autor:innen. Beteiligte Einrichtung: One Welfare and Sustainability Center, College of Veterinary Medicine, The Ohio State University, Columbus, Ohio, United States of America. Hauptthemen laut MEDLINE: Acinonyx, Glomerular Filtration Rate, Iohexol, Arginine. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Morris Animal Foundation.
Abstract (Originalsprache)
One of the more common diseases affecting zoo-managed cheetahs ( Acinonyx jubatus ) is chronic renal disease, which can impact their welfare and ultimately shortens their lifespan. Early diagnosis, for which estimating Glomerular Filtration Rate (GFR) is one such tool, is imperative to help mitigate the negative impacts of this insidious disease. GFR was determined by measuring the serum clearance of iohexol in nine clinically normal, cheetahs managed under human care that presented for voluntary blood collection. A 2-sample iohexol clearance method was performed, along with serum symmetric dimethylarginine (SDMA) determination. SDMA has shown promise in humans, dogs, and cats, as an early biomarker of renal disease. Additionally, the relationship between GFR and SDMA, along with serum creatinine and BUN were analyzed. The mean values for the uncorrected GFR and corrected GFR were 2.08 ± 0.215 mL/min/kg body weight and 1.87 ± 0.173 mL/min/kg body weight, respectively. No significant correlations were observed between GFR, SDMA, serum creatinine, or BUN. Both the uncorrected and corrected iohexol-based GFR values were similar to an inulin-based GFR reference interval determined in zoo managed cheetahs and a reported domestic cat iohexol-based GFR reference interval. Serum SDMA values support previous research suggesting cheetahs have a separate reference interval from domestic cats (0–14 μg/dL). Measuring GFR by the serum clearance of iohexol shows promise as a readily available, cheap, and easily administered clearance marker that can be used in cheetahs trained for voluntary blood collection, thereby avoiding the need for anesthesia.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- One Welfare and Sustainability Center, College of Veterinary Medicine, The Ohio State University, Columbus, Ohio, United States of America.
- Columbus Zoo and Aquarium, Powell, Ohio, United States of America.
ORCID-Profile: Nicholas Lordi
Förderung
- Morris Animal Foundation
Zitieren
APA
Lordi, N., Bapodra-Villaverde, P., & Flint, M. (2024). Glomerular filtration rate determined by measuring serum clearance of iohexol in unanesthetized cheetahs (Acinonyx jubatus) with comparison to serum symmetric dimethylarginine. PLOS ONE, 19(10), e0311406. https://doi.org/10.1371/journal.pone.0311406
Vancouver
Lordi N, Bapodra-Villaverde P, Flint M. Glomerular filtration rate determined by measuring serum clearance of iohexol in unanesthetized cheetahs (Acinonyx jubatus) with comparison to serum symmetric dimethylarginine. PLOS ONE. 2024;19(10):e0311406. doi:10.1371/journal.pone.0311406
BibTeX
@article{Lordi2024,
author = {Lordi, Nicholas and Bapodra-Villaverde, Priya and Flint, Mark},
title = {Glomerular filtration rate determined by measuring serum clearance of iohexol in unanesthetized cheetahs (Acinonyx jubatus) with comparison to serum symmetric dimethylarginine},
journal = {PLOS ONE},
year = {2024},
volume = {19},
number = {10},
pages = {e0311406},
doi = {10.1371/journal.pone.0311406}
}
EUVIMED