EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The reproducibility and predictivity of radiomic features extracted from dynamic contrast-enhanced computed tomography of hepatocellular carcinoma

Abdalla Ibrahim iD, Siddharth Guha, Lin Lu, Pengfei Geng, Qian Wu, Yen Chou, Hao Yang, Delin Wang, Lawrence H Schwartz, Chuan-Miao Xie, Binsheng Zhao

PLOS ONE · 13.09.2024 · 19 (9) · e0310486

DOI: 10.1371/journal.pone.0310486 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 13.09.2024. Verfasst von Abdalla Ibrahim und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, United States of America. Hauptthemen laut MEDLINE: Carcinoma, Hepatocellular, Liver Neoplasms, Tomography, X-Ray Computed, Contrast Media. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To assess the reproducibility of radiomic features (RFs) extracted from dynamic contrast-enhanced computed tomography (DCE-CT) scans of patients diagnosed with hepatocellular carcinoma (HCC) with regards to inter-observer variability and acquisition timing after contrast injection. The predictive ability of reproducible RFs for differentiating between the degrees of HCC differentiation is also investigated.

Methods

We analyzed a set of DCE-CT scans of 39 patients diagnosed with HCC. Two radiologists independently segmented the scans, and RFs were extracted from each sequence of the DCE-CT scans. The same lesion was segmented across the DCE-CT sequences of each patient’s scan. From each lesion, 127 commonly used RFs were extracted. The reproducibility of RFs was assessed with regard to (i) inter-observer variability, by evaluating the reproducibility of RFs between the two radiologists; and (ii) timing of acquisition following contrast injection (inter- and intra-imaging phase). The reproducibility of RFs was assessed using the concordance correlation coefficient (CCC), with a cut-off value of 0.90. Reproducible RFs were used for building XGBoost classification models for the differentiation of HCC differentiation.

Results

Inter-observer analyses across the different contrast-enhancement phases showed that the number of reproducible RFs was 29 (22.8%), 52 (40.9%), and 36 (28.3%) for the non-contrast enhanced, late arterial, and portal venous phases, respectively. Intra- and inter-sequence analyses revealed that the number of reproducible RFs ranged between 1 (0.8%) and 47 (37%), inversely related with time interval between the sequences. XGBoost algorithms built using reproducible RFs in each phase were found to be high predictive ability of the degree of HCC tumor differentiation.

Conclusions

The reproducibility of many RFs was significantly impacted by inter-observer variability, and a larger number of RFs were impacted by the difference in the time of acquisition after contrast injection. Our findings highlight the need for quality assessment to ensure that scans are analyzed in the same physiologic imaging phase in quantitative imaging studies, or that phase-wide reproducible RFs are selected. Overall, the study emphasizes the importance of reproducibility and quality control when using RFs as biomarkers for clinical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carcinoma, HepatocellularLiver NeoplasmsTomography, X-Ray ComputedContrast MediaObserver VariationHumansMaleFemaleReproducibility of ResultsMiddle AgedAgedAdultRadiomics

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, United States of America.
  • Department of Radiology, Columbia University Irving Medical Center, New York, New York, United States of America.
  • First Affiliated Hospital of Nanjing Medical University, Jiangsu, China.
  • Department of Medical Imaging, Fu Jen Catholic University Hospital, New Taipei City, Taiwan.
  • Department of Radiology, Sun Yat-Sen University Cancer Center, Guangzhou, China.

ORCID-Profile: Abdalla Ibrahim

Förderung

  • NCI NIH HHS

Zitieren

APA

Ibrahim, A., Guha, S., Lu, L., Geng, P., Wu, Q., Chou, Y., Yang, H., Wang, D., Schwartz, L. H., Xie, C. M., & Zhao, B. (2024). The reproducibility and predictivity of radiomic features extracted from dynamic contrast-enhanced computed tomography of hepatocellular carcinoma. PLOS ONE, 19(9), e0310486. https://doi.org/10.1371/journal.pone.0310486

Vancouver

Ibrahim A, Guha S, Lu L, Geng P, Wu Q, Chou Y, et al. The reproducibility and predictivity of radiomic features extracted from dynamic contrast-enhanced computed tomography of hepatocellular carcinoma. PLOS ONE. 2024;19(9):e0310486. doi:10.1371/journal.pone.0310486

BibTeX
@article{Ibrahim2024,
  author = {Ibrahim, Abdalla and Guha, Siddharth and Lu, Lin and Geng, Pengfei and Wu, Qian and Chou, Yen and Yang, Hao and Wang, Delin and Schwartz, Lawrence H and Xie, Chuan-Miao and Zhao, Binsheng},
  title = {The reproducibility and predictivity of radiomic features extracted from dynamic contrast-enhanced computed tomography of hepatocellular carcinoma},
  journal = {PLOS ONE},
  year = {2024},
  volume = {19},
  number = {9},
  pages = {e0310486},
  doi = {10.1371/journal.pone.0310486}
}
Kostenlos starten →