EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of simplified wireless EEG recordings in the neurological emergency room

Tamara M Welte iD, Felix Janner, Sara Lindner, Stephanie Gollwitzer, Jenny Stritzelberger, Johannes D Lang, Caroline Reindl, Maximilian I Sprügel, David Olmes, Stefan Schwab, Christian Blinzler, Hajo M Hamer

PLOS ONE · 2024

DOI: 10.1371/journal.pone.0310223 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Tamara M Welte und 11 weiteren Autor:innen. Beteiligte Einrichtung: Full member of ERN EpiCARE, Epilepsy Center, Department of Neurology, University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nürnberg,…. Hauptthemen laut MEDLINE: Electroencephalography, Emergency Service, Hospital. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nihon Kohden Europe.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

In the neurological emergency room (nER), timely electroencephalography (EEG) diagnostic is often crucial in patients with altered state of consciousness as well as in patients presenting with a first seizure. Yet, routine-EEG (rEEG) is often not available, especially during off-hours.

Methods

We analyzed the value of a commercially available, simplified wireless eight-channel EEG recording (swEEG, CerebAir ® EEG headset, Nihon Kohden), applied by non-EEG-specialized medical students, in patients presenting in our nER with (suspicion of) epileptic seizures and/or loss of or altered state of consciousness between 08/2019 and 08/2022. We evaluated the feasibility and validity compared to a standard rEEG (21 electrodes according to the international 10/20 system) and also included the clinical follow-up of the patients.

Results

100 patients were included in our analysis (mean age 57.6 ± 20.4 years; 61 male). Median time of electrode application was 7 minutes (range 4–20 minutes), with significantly longer duration in patients with altered level of consciousness (median 8 minutes, p = 0.035). Electrode impedances also differed according to state of consciousness (p = 0.032), and were higher in females (p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectroencephalographyEmergency Service, HospitalHumansFemaleMaleMiddle AgedAdultAgedSeizuresWireless TechnologyEpilepsyElectrodesYoung AdultAged, 80 and over

Autor:innen und Institutionen

  • Full member of ERN EpiCARE, Epilepsy Center, Department of Neurology, University Hospital Erlangen, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany.
  • Department of Neurology, University Hospital Regensburg, Regensburg, Germany.

ORCID-Profile: Tamara M Welte

Förderung

  • Nihon Kohden Europe

Zitieren

APA

Welte, T. M., Janner, F., Lindner, S., Gollwitzer, S., Stritzelberger, J., Lang, J. D., Reindl, C., Sprügel, M. I., Olmes, D., Schwab, S., Blinzler, C., & Hamer, H. M. (2024). Evaluation of simplified wireless EEG recordings in the neurological emergency room. PLOS ONE. https://doi.org/10.1371/journal.pone.0310223

Vancouver

Welte TM, Janner F, Lindner S, Gollwitzer S, Stritzelberger J, Lang JD, et al. Evaluation of simplified wireless EEG recordings in the neurological emergency room. PLOS ONE. 2024. doi:10.1371/journal.pone.0310223

BibTeX
@article{Welte2024,
  author = {Welte, Tamara M and Janner, Felix and Lindner, Sara and Gollwitzer, Stephanie and Stritzelberger, Jenny and Lang, Johannes D and Reindl, Caroline and Sprügel, Maximilian I and Olmes, David and Schwab, Stefan and Blinzler, Christian and Hamer, Hajo M},
  title = {Evaluation of simplified wireless EEG recordings in the neurological emergency room},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0310223}
}
Kostenlos starten →