CD11c+ dendritic cells PlexinD1 deficiency exacerbates airway hyperresponsiveness, IgE and mucus production in a mouse model of allergic asthma
PLOS ONE · 30.08.2024 · 19 (8) · e0309868
DOI: 10.1371/journal.pone.0309868 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 30.08.2024. Verfasst von Lianyu Shan und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Immunology, Rady Faculty of Health Sciences, Max Rady College of Medicine, University of Manitoba, Winnipeg, Manitoba, Canada. Hauptthemen laut MEDLINE: Asthma, Dendritic Cells, Immunoglobulin E, Mice, Knockout. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 74 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Institute of Circulatory and Respiratory Health.
Abstract (Originalsprache)
Dendritic cells (DCs) are pivotal in regulating allergic asthma. Our research has shown that the absence of Sema3E worsens asthma symptoms in acute and chronic asthma models. However, the specific role of PlexinD1 in these processes, particularly in DCs, remains unclear. This study investigates the role of PlexinD1 in CD11c+ DCs using a house dust mite (HDM) model of asthma. We generated CD11c+ DC-specific PlexinD1 knockout ( CD11c PLXND1 KO ) mice and subjected them, alongside wild-type controls ( PLXND1 fl/fl ), to an HDM allergen protocol. Airway hyperresponsiveness (AHR) was measured using FlexiVent, and immune cell populations were analyzed via flow cytometry. Cytokine levels and immunoglobulin concentrations were assessed using mesoscale and ELISA, while collagen deposition and mucus production were examined through Sirius-red and periodic acid Schiff (PAS) staining respectively. Our results indicate that CD11c PLXND1 KO mice exhibit significantly exacerbated AHR, characterized by increased airway resistance and tissue elastance. Enhanced mucus production and collagen gene expression were observed in these mice compared to wild-type counterparts. Flow cytometry revealed higher CD11c+ MHCII high CD11b+ cell recruitment into the lungs, and elevated total and HDM-specific serum IgE levels in CD11c PLXND1 KO mice. Mechanistically, co-cultures of B cells with DCs from CD11c PLXND1 KO mice showed significantly increased IgE production compared to wild-type mice.These findings highlight the critical regulatory role of the plexinD1 signaling pathway in CD11c+ DCs in modulating asthma features.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Immunology, Rady Faculty of Health Sciences, Max Rady College of Medicine, University of Manitoba, Winnipeg, Manitoba, Canada.
- Department of Anatomy, Rady Faculty of Health Sciences, Max Rady College of Medicine, University of Manitoba, Winnipeg, Manitoba, Canada.
- Depertment of Physiology and Pathophysiology, Rady Faculty of Health Sciences, Max Rady College of Medicine, University of Manitoba, Winnipeg, Manitoba, Canada.
- Department of Experimental Biology, Université de Saint-Boniface, Winnipeg, Manitoba.
ORCID-Profile: Abdelilah S Gounni
Förderung
- Institute of Circulatory and Respiratory Health
Zitieren
APA
Shan, L., Matloubi, M., Okwor, I., Kung, S., Almiski, M. S., Basu, S., Halayko, A., Koussih, L., & Gounni, A. S. (2024). CD11c+ dendritic cells PlexinD1 deficiency exacerbates airway hyperresponsiveness, IgE and mucus production in a mouse model of allergic asthma. PLOS ONE, 19(8), e0309868. https://doi.org/10.1371/journal.pone.0309868
Vancouver
Shan L, Matloubi M, Okwor I, Kung S, Almiski MS, Basu S, et al. CD11c+ dendritic cells PlexinD1 deficiency exacerbates airway hyperresponsiveness, IgE and mucus production in a mouse model of allergic asthma. PLOS ONE. 2024;19(8):e0309868. doi:10.1371/journal.pone.0309868
BibTeX
@article{Shan2024,
author = {Shan, Lianyu and Matloubi, Mojdeh and Okwor, Ifeoma and Kung, Sam and Almiski, Mohamed Sadek and Basu, Sujata and Halayko, Andrew and Koussih, Latifa and Gounni, Abdelilah S},
title = {CD11c+ dendritic cells PlexinD1 deficiency exacerbates airway hyperresponsiveness, IgE and mucus production in a mouse model of allergic asthma},
journal = {PLOS ONE},
year = {2024},
volume = {19},
number = {8},
pages = {e0309868},
doi = {10.1371/journal.pone.0309868}
}
EUVIMED