EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessment of a multiplex arbovirus PCR Detection Test in an area endemic for Chikungunya, Zika, and Dengue viruses: An evaluation of kit performance characteristics in line with Clinical Laboratory Improvement Amendments (CLIA) Standards

Leonard Kingwara iD, Lazarus Odeny iD, Vera Onwonga, Rukia Madada, Marygorett Mbeneka, Jully Okonji, Victoria Mwende, Charles Rombo, Shalyn Akasa, Millicent Ndia, Fredrick Ouma iD, Isabella Ayagah und 2 weitere

PLOS One · 2025

DOI: 10.1371/journal.pone.0309626 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS One, 2025. Verfasst von Leonard Kingwara und 13 weiteren Autor:innen. Beteiligte Einrichtung: Kenya National Public Health Institute, Kenya. Hauptthemen laut MEDLINE: Zika Virus, Chikungunya virus, Dengue Virus, Chikungunya Fever. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Government of the Republic of Kenya.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Several multiplex and singleplex PCR systems exist for the detection of Dengue(DENV), Zika(ZIKV), and Chikungunya(CHIKV) viruses; however, their performance characteristics in East Africa remain unassessed. In this study, we investigated the TaqMan® Arbovirus Triplex Kit, which allows for the simultaneous identification of CHIKV, DENV, and ZIKV viruses in serum samples and singleplex assays, including the RealStar® Chikungunya RT-PCR Kit 2.0, RealStar® Dengue RT-PCR Kit 3.0, and RealStar® Zika Virus RT-PCR Kit 1.0.

Methods

We used Clinical Laboratory Improvement validation methods and residual specimens sourced from DENV, CHIKV, and ZIKV outbreaks, from Kenya, Brazil, and the Democratic Republic of Congo(DRC) in March 2024. Quality control was ensured through Quality Control for Medical diagnostics (QCMD) commercial positive panels. Gold standard results were established through consensus from multiple kits, including the TaqMan® Arbovirus Triplex Kit, Illumina viral surveillance panel (Illumina VSP), and Altona singleplex kit. Data were analyzed using R to determine specificity, sensitivity, negative predictive value (NPV), positive predictive value (PPV), and diagnostic odds ratio, with probit analysis employed to evaluate the limit of detection.

Results

The TaqMan® Arbovirus Kit showed sensitivity exceeding 95% for all three virus targets: 97.98% for DENV, and 100% for both CHIKV and ZIKV. Simillarly, the RealStar® RT-PCR Kits exhibited sensitivities: 93.94% for CHIKV, 90.91% for DENV, and 100% for ZIKV. All kits demonstrated specificity above 99%, with a positive predictive value (PPV) over 99% and a negative predictive value (NPV) exceeding 97%. Probit analysis revealed that the TaqMan® Arbovirus Kit also had a lower detection limit compared to the RealStar kit for all tested viruses.

Conclusion

The TaqMan® Arbovirus Kit provides multiplex capabilities and performance similar to the RealStar® CHIKV, DENV, and ZIKV RT-PCR Kits. Consequently, these kits can be used interchangeably for detecting DENV, CHIKV, and ZIKV viruses in outbreak situations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Zika VirusChikungunya virusDengue VirusChikungunya FeverMultiplex Polymerase Chain ReactionDengueZika Virus InfectionHumansSensitivity and SpecificityReagent Kits, DiagnosticBrazilKenyaArbovirusesDemocratic Republic of the Congo

Substanzen

Reagent Kits, Diagnostic

Autor:innen und Institutionen

  • Kenya National Public Health Institute, Kenya.
  • Amref Health Africa, Africa.

ORCID-Profile: Leonard Kingwara, Lazarus Odeny, Fredrick Ouma

Förderung

  • Government of the Republic of Kenya

Zitieren

APA

Kingwara, L., Odeny, L., Onwonga, V., Madada, R., Mbeneka, M., Okonji, J., Mwende, V., Rombo, C., Akasa, S., Ndia, M., Ouma, F., Ayagah, I., Roba, A., & Kimenye, K. (2025). Assessment of a multiplex arbovirus PCR Detection Test in an area endemic for Chikungunya, Zika, and Dengue viruses: An evaluation of kit performance characteristics in line with Clinical Laboratory Improvement Amendments (CLIA) Standards. PLOS One. https://doi.org/10.1371/journal.pone.0309626

Vancouver

Kingwara L, Odeny L, Onwonga V, Madada R, Mbeneka M, Okonji J, et al. Assessment of a multiplex arbovirus PCR Detection Test in an area endemic for Chikungunya, Zika, and Dengue viruses: An evaluation of kit performance characteristics in line with Clinical Laboratory Improvement Amendments (CLIA) Standards. PLOS One. 2025. doi:10.1371/journal.pone.0309626

BibTeX
@article{Kingwara2025,
  author = {Kingwara, Leonard and Odeny, Lazarus and Onwonga, Vera and Madada, Rukia and Mbeneka, Marygorett and Okonji, Jully and Mwende, Victoria and Rombo, Charles and Akasa, Shalyn and Ndia, Millicent and Ouma, Fredrick and Ayagah, Isabella and Roba, Abdi and Kimenye, Kamene},
  title = {Assessment of a multiplex arbovirus PCR Detection Test in an area endemic for Chikungunya, Zika, and Dengue viruses: An evaluation of kit performance characteristics in line with Clinical Laboratory Improvement Amendments (CLIA) Standards},
  journal = {PLOS One},
  year = {2025},
  doi = {10.1371/journal.pone.0309626}
}
Kostenlos starten →