Vertical implantable collamer lens as a novel method to increase rotational stability
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0308830 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift PLOS ONE, 2024. Verfasst von Yongwoo Lee und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Kangwon National University Hospital, Kangwon National University School of Medicine, Chuncheon, Republic of Korea. Hauptthemen laut MEDLINE: Lens Implantation, Intraocular, Visual Acuity, Phakic Intraocular Lenses, Astigmatism. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The 2024 Kangwon National University Hospital Grant.
Abstract (Originalsprache)
Purpose
We investigated the vertical implantation of a toric implantable collamer lens (ICL) and compared the rotational stability with that of horizontal implantation.
Methods
This matched comparative study retrospectively reviewed and analyzed data from patients who underwent ICL implantation from 2003–2022 by 1:1 matching vertical and horizontal (V and H toric groups, respectively) implantation patients according to preoperative astigmatism, spherical equivalent, sulcus-to-sulcus, anterior chamber depth, and ICL size. Visual acuity, manifest refraction, vaulting, and rotation were measured 3 months postoperatively.
Results
We included 646 eyes (323 each in the V and H toric groups). No statistically significant difference was observed between groups in postoperative visual acuity, refractive error, and astigmatism. Vaulting was lower in the V toric group. (P < 0.001). The mean lens rotation in the V toric group was less than that in the H toric group (1.11 ± 2.84° versus 3.02 ± 10.34°, P = 0.001). The proportion of eyes in the V and H toric groups showing ≥10° of rotation was 2.5% (8 eyes) and 6.5% (21 eyes), respectively (P = 0.014). Despite repositioning from rotation, three (0.9%) and eight (2.5%) eyes required removal owing to lens re-rotation in the V and H toric groups, respectively.
Conclusion
Toric ICL vertical implantation showed good rotational stability, and appropriate visual acuity correction results with relatively low vaulting. This procedure therefore presents an effective novel method that could replace horizontal toric ICL implantation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Ophthalmology, Kangwon National University Hospital, Kangwon National University School of Medicine, Chuncheon, Republic of Korea.
- Saevit Eye Hospital, Goyang, Republic of Korea.
- The David J. Apple International Laboratory for Ocular Pathology and International Vision Correction Research Centre (IVCRC), Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany.
- Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
- Seoulbalgeunsesang Eye Clinic, Seoul, Republic of Korea.
ORCID-Profile: Yongwoo Lee, Ramin Khoramnia, Chul Young Choi
Förderung
- The 2024 Kangwon National University Hospital Grant
Zitieren
APA
Lee, Y., Han, S. B., Auffarth, G. U., Son, H. S., Khoramnia, R., Choi, C. Y., Moon, K., An, S. I., Lee, J. M., & Lee, J. H. (2024). Vertical implantable collamer lens as a novel method to increase rotational stability. PLOS ONE. https://doi.org/10.1371/journal.pone.0308830
Vancouver
Lee Y, Han SB, Auffarth GU, Son HS, Khoramnia R, Choi CY, et al. Vertical implantable collamer lens as a novel method to increase rotational stability. PLOS ONE. 2024. doi:10.1371/journal.pone.0308830
BibTeX
@article{Lee2024,
author = {Lee, Yongwoo and Han, Sang Beom and Auffarth, Gerd U and Son, Hyeck-Soo and Khoramnia, Ramin and Choi, Chul Young and Moon, Kun and An, Sang Il and Lee, Je Myung and Lee, Jong Ho},
title = {Vertical implantable collamer lens as a novel method to increase rotational stability},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0308830}
}
EUVIMED