Cardiac magnetic resonance imaging in repaired tetralogy of Fallot: A longitudinal midterm follow-up study
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0308362 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Golnaz Houshmand und 11 weiteren Autor:innen. Beteiligte Einrichtung: Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran. Hauptthemen laut MEDLINE: Tetralogy of Fallot, Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Biventricular dysfunction is frequent in patients with repaired tetralogy of Fallot, necessitating routine imaging to monitor for worsening conditions and determine whether procedures like pulmonary valve replacement (PVR) are needed. This study aimed to highlight the parameters of cardiac magnetic resonance imaging (CMR) and their association with adverse outcomes in the midterm follow-up of these patients.
Methods
This longitudinal study recruited all patients with a history of tetralogy of Fallot total correction (TFTC) who had two CMR images at a minimum three-month interval at Rajaie Center from 2007 through 2017.
Results
Fifty-six patients at a mean age of 15.23 ± 11.66 years at TFTC and a 1:1 gender distribution were assessed. Regarding adverse events, PVR was done on 18 patients (32%). Right and left ventricular dysfunction occurred in 43 (76.8%) and 18 (32.1%) patients, respectively. Death did not occur in the present study. RVOT fibrosis was present in 47 (92.2%). The stroke volume of both ventricles increased during the follow-up ( P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran.
- Students Research Committee, Shahrekord University of Medical Sciences, Shahrekord, Iran.
- Cardiovascular Disease Research Institute, Tehran Heart Center, Tehran University of Medical Science, Tehran, Iran.
- Students' Scientific Research Center, Tehran University of Medical Sciences, Tehran, Iran.
- Cardiovascular Disease Research Institute, Cardiac Primary Prevention Research Center, Tehran University of Medical Science, Tehran, Iran.
ORCID-Profile: Rahem Rahmati, Negar Omidi, Hamidreza Pouraliakbar
Zitieren
APA
Houshmand, G., Rahmati, R., Meftah, E., Zarimeidani, F., Khorgami, M., Ghorashi, S. M., Fazeli, A., Omidi, N., Saedi, S., Motevalli, M., Maleki, M., & Pouraliakbar, H. (2024). Cardiac magnetic resonance imaging in repaired tetralogy of Fallot: A longitudinal midterm follow-up study. PLOS ONE. https://doi.org/10.1371/journal.pone.0308362
Vancouver
Houshmand G, Rahmati R, Meftah E, Zarimeidani F, Khorgami M, Ghorashi SM, et al. Cardiac magnetic resonance imaging in repaired tetralogy of Fallot: A longitudinal midterm follow-up study. PLOS ONE. 2024. doi:10.1371/journal.pone.0308362
BibTeX
@article{Houshmand2024,
author = {Houshmand, Golnaz and Rahmati, Rahem and Meftah, Elahe and Zarimeidani, Fatemeh and Khorgami, Mohammadrafi and Ghorashi, Seyyed Mojtaba and Fazeli, Amir and Omidi, Negar and Saedi, Sedigheh and Motevalli, Marzieh and Maleki, Majid and Pouraliakbar, Hamidreza},
title = {Cardiac magnetic resonance imaging in repaired tetralogy of Fallot: A longitudinal midterm follow-up study},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0308362}
}
EUVIMED