Effect of automated versus conventional ventilation on mechanical power of ventilation—A randomized crossover clinical trial
PLOS ONE · 30.07.2024 · 19 (7) · e0307155
DOI: 10.1371/journal.pone.0307155 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift PLOS ONE, online erschienen am 30.07.2024. Verfasst von Laura A Buiteman-Kruizinga und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Intensive Care, Reinier de Graaf Hospital, Delft, the Netherlands. Hauptthemen laut MEDLINE: Cross-Over Studies, Respiration, Artificial, Critical Illness. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Mechanical power of ventilation, a summary parameter reflecting the energy transferred from the ventilator to the respiratory system, has associations with outcomes. INTELLiVENT–Adaptive Support Ventilation is an automated ventilation mode that changes ventilator settings according to algorithms that target a low work–and force of breathing. The study aims to compare mechanical power between automated ventilation by means of INTELLiVENT–Adaptive Support Ventilation and conventional ventilation in critically ill patients. Materials and methods International, multicenter, randomized crossover clinical trial in patients that were expected to need invasive ventilation > 24 hours. Patients were randomly assigned to start with a 3–hour period of automated ventilation or conventional ventilation after which the alternate ventilation mode was selected. The primary outcome was mechanical power in passive and active patients; secondary outcomes included key ventilator settings and ventilatory parameters that affect mechanical power.
Results
A total of 96 patients were randomized. Median mechanical power was not different between automated and conventional ventilation (15.8 [11.5–21.0] versus 16.1 [10.9–22.6] J/min; mean difference –0.44 (95%–CI –1.17 to 0.29) J/min; P = 0.24). Subgroup analyses showed that mechanical power was lower with automated ventilation in passive patients, 16.9 [12.5–22.1] versus 19.0 [14.1–25.0] J/min; mean difference –1.76 (95%–CI –2.47 to –10.34J/min; P < 0.01), and not in active patients (14.6 [11.0–20.3] vs 14.1 [10.1–21.3] J/min; mean difference 0.81 (95%–CI –2.13 to 0.49) J/min; P = 0.23).
Conclusions
In this cohort of unselected critically ill invasively ventilated patients, automated ventilation by means of INTELLiVENT–Adaptive Support Ventilation did not reduce mechanical power. A reduction in mechanical power was only seen in passive patients. Study registration Clinicaltrials.gov (study identifier NCT04827927), April 1, 2021 URL of trial registry record https://clinicaltrials.gov/study/NCT04827927?term=intellipower&rank=1
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Intensive Care, Reinier de Graaf Hospital, Delft, the Netherlands.
- Department of Intensive Care, Amsterdam University Medical Centers 'Location AMC', Amsterdam, the Netherlands.
- Australian and New Zealand Intensive Care-Research Centre (ANZIC-RC), Monash University, Melbourne, Australia.
- Department of Intensive Care, Austin Hospital, Melbourne, Australia.
- Department of Critical Care, University of Melbourne, Melbourne, Australia.
- Department of Critical Care Medicine, Hospital Israelita Albert Einstein, São Paulo, Brazil.
ORCID-Profile: Laura A Buiteman-Kruizinga, Michela Botta
Zitieren
APA
Buiteman-Kruizinga, L. A., Serpa Neto, A., Botta, M., List, S. S., de Boer, B. H., van Velzen, P., Bühler, P. K., Wendel Garcia, P. D., Schultz, M. J., van der Heiden, P. L. J., Paulus, F., & INTELLiPOWER–investigators (2024). Effect of automated versus conventional ventilation on mechanical power of ventilation—A randomized crossover clinical trial. PLOS ONE, 19(7), e0307155. https://doi.org/10.1371/journal.pone.0307155
Vancouver
Buiteman-Kruizinga LA, Serpa Neto A, Botta M, List SS, de Boer BH, van Velzen P, et al. Effect of automated versus conventional ventilation on mechanical power of ventilation—A randomized crossover clinical trial. PLOS ONE. 2024;19(7):e0307155. doi:10.1371/journal.pone.0307155
BibTeX
@article{BuitemanKruizinga2024,
author = {Buiteman-Kruizinga, Laura A and Serpa Neto, Ary and Botta, Michela and List, Stephanie S and de Boer, Ben H and van Velzen, Patricia and Bühler, Philipp Karl and Wendel Garcia, Pedro D and Schultz, Marcus J and van der Heiden, Pim L J and Paulus, Frederique and INTELLiPOWER–investigators, INTELLiPOWER–investigators},
title = {Effect of automated versus conventional ventilation on mechanical power of ventilation—A randomized crossover clinical trial},
journal = {PLOS ONE},
year = {2024},
volume = {19},
number = {7},
pages = {e0307155},
doi = {10.1371/journal.pone.0307155}
}
EUVIMED