VMseg: Using spatial variance to automatically segment retinal non-perfusion on OCT-angiography
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0306794 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Hugo LE Boite und 4 weiteren Autor:innen. Beteiligte Einrichtung: Université Paris Cité, Paris, France. Hauptthemen laut MEDLINE: Diabetic Retinopathy, Algorithms, Tomography, Optical Coherence. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background and objectives To develop and test VMseg, a new image processing algorithm performing automatic segmentation of retinal non-perfusion in widefield OCT-Angiography images, in order to estimate the non-perfusion index in diabetic patients.
Methods
We included diabetic patients with severe non-proliferative or proliferative diabetic retinopathy. We acquired images using the PlexElite 9000 OCT-A device with a photomontage of 5 images of size 12 x 12 mm. We then developed VMseg, a Python algorithm for non-perfusion detection, which binarizes a variance map calculated through convolution and morphological operations. We used 70% of our data set (development set) to fine-tune the algorithm parameters (convolution and morphological parameters, binarization thresholds) and evaluated the algorithm performance on the remaining 30% (test set). The obtained automatic segmentations were compared to a ground truth corresponding to manual segmentation from a retina expert and the inference processing time was estimated.
Results
We included 51 eyes of 30 patients (27 severe non-proliferative, 24 proliferative diabetic retinopathy). Using the optimal parameters found on the development set to tune the algorithm, the mean dice for the test set was 0.683 (sd = 0.175). We found a higher dice coefficient for images with a higher area of retinal non-perfusion (r s = 0.722, p < 10 −4 ). There was a strong correlation (r s = 0.877, p < 10 −4 ) between VMseg estimated non-perfusion indexes and indexes estimated using the ground truth segmentation. The Bland-Altman plot revealed that 3 eyes (5.9%) were significantly under-segmented by VMseg.
Conclusion
We developed VMseg, an automatic algorithm for retinal non-perfusion segmentation on 12 x 12 mm OCT-A widefield photomontages. This simple algorithm was fast at inference time, segmented images in full-resolution and for the OCT-A format, was accurate enough for automatic estimation of retinal non-perfusion index in diabetic patients with diabetic retinopathy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Université Paris Cité, Paris, France.
- Ophthalmology Department, AP-HP, Hôpital Lariboisière, Paris, France.
- Université de Bretagne Occidentale, Brest, France.
- LaTIM, INSERM UMR 1101, Brest, France.
ORCID-Profile: Hugo LE Boite, Aude Couturier, Gwenolé Quellec
Zitieren
APA
LE Boite, H., Couturier, A., Tadayoni, R., Lamard, M., & Quellec, G. (2024). VMseg: Using spatial variance to automatically segment retinal non-perfusion on OCT-angiography. PLOS ONE. https://doi.org/10.1371/journal.pone.0306794
Vancouver
LE Boite H, Couturier A, Tadayoni R, Lamard M, Quellec G. VMseg: Using spatial variance to automatically segment retinal non-perfusion on OCT-angiography. PLOS ONE. 2024. doi:10.1371/journal.pone.0306794
BibTeX
@article{LEBoite2024,
author = {LE Boite, Hugo and Couturier, Aude and Tadayoni, Ramin and Lamard, Mathieu and Quellec, Gwenolé},
title = {VMseg: Using spatial variance to automatically segment retinal non-perfusion on OCT-angiography},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0306794}
}
EUVIMED