EUVIMEDEUVIMED entdecken
Multizentrische StudieKlinische StudieOpen Access · CC BY 4.0

Therapy effect on hand function after home use of a wearable assistive soft-robotic glove supporting grip strength

Anke I R Kottink iD, Corien D M Nikamp, Foskea P Bos, Corry K van der Sluis, Marieke van den Broek, Bram Onneweer, Janneke M Stolwijk-Swüste, Sander M Brink iD, Nicoline B M Voet, Johan S Rietman, Gerdienke B Prange-Lasonder

PLOS ONE · 2024

DOI: 10.1371/journal.pone.0306713 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift PLOS ONE, 2024. Verfasst von Anke I R Kottink und 10 weiteren Autor:innen. Beteiligte Einrichtung: Roessingh Research and Development, Enschede, The Netherlands. Hauptthemen laut MEDLINE: Hand Strength, Hand, Wearable Electronic Devices. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Horizon 2020 Framework Programme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Soft-robotic gloves with an assist-as-needed control have the ability to assist daily activities where needed, while stimulating active and highly functional movements within the user’s possibilities. Employment of hand activities with glove support might act as training for unsupported hand function.

Objective

To evaluate the therapeutic effect of a grip-supporting soft-robotic glove as an assistive device at home during daily activities.

Methods

This multicentre intervention trial consisted of 3 pre-assessments (averaged if steady state = PRE), one post-assessment (POST), and one follow-up assessment (FU). Participants with chronic hand function limitations were included. Participants used the Carbonhand glove during six weeks in their home environment on their most affected hand. They were free to choose which activities to use the glove with and for how long. The primary outcome measure was grip strength, secondary outcome measures were pinch strength, hand function and glove use time.

Results

63 patients with limitations in hand function resulting from various disorders were included. Significant improvements (difference PRE-POST) were found for grip strength (+1.9 kg, CI 0.8 to 3.1; p = 0.002) and hand function, as measured by Jebson-Taylor Hand Function Test (-7.7 s, CI -13.4 to -1.9; p = 0.002) and Action Research Arm Test (+1.0 point, IQR 2.0; p≤0.001). Improvements persisted at FU. Pinch strength improved slightly in all fingers over six-week glove use, however these differences didn’t achieve significance. Participants used the soft-robotic glove for a total average of 33.0 hours (SD 35.3), equivalent to 330 min/week (SD 354) or 47 min/day (SD 51). No serious adverse events occurred.

Conclusion

The present findings showed that six weeks use of a grip-supporting soft-robotic glove as an assistive device at home resulted in a therapeutic effect on unsupported grip strength and hand function. The glove use time also showed that this wearable, lightweight glove was able to assist participants with the performance of daily tasks for prolonged periods.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hand StrengthHandWearable Electronic DevicesHumansFemaleMaleMiddle AgedAdultAgedSelf-Help DevicesRoboticsActivities of Daily Living

Autor:innen und Institutionen

  • Roessingh Research and Development, Enschede, The Netherlands.
  • Department of Biomechanical Engineering, University of Twente, Enschede, The Netherlands.
  • Department of Biomedical Signals and Systems, University of Twente, Enschede, The Netherlands.
  • Reade, Center for Rehabilitation and Rheumatology, Amsterdam, The Netherlands.
  • Department of Rehabilitation Medicine, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.
  • Sint Maartenskliniek, Ubbergen, The Netherlands.

ORCID-Profile: Anke I R Kottink, Sander M Brink

Förderung

  • Horizon 2020 Framework Programme

Zitieren

APA

Kottink, A. I. R., Nikamp, C. D. M., Bos, F. P., Sluis, C. K. V., Broek, M. V. D., Onneweer, B., Stolwijk-Swüste, J. M., Brink, S. M., Voet, N. B. M., Rietman, J. S., & Prange-Lasonder, G. B. (2024). Therapy effect on hand function after home use of a wearable assistive soft-robotic glove supporting grip strength. PLOS ONE. https://doi.org/10.1371/journal.pone.0306713

Vancouver

Kottink AIR, Nikamp CDM, Bos FP, Sluis CKV, Broek MVD, Onneweer B, et al. Therapy effect on hand function after home use of a wearable assistive soft-robotic glove supporting grip strength. PLOS ONE. 2024. doi:10.1371/journal.pone.0306713

BibTeX
@article{Kottink2024,
  author = {Kottink, Anke I R and Nikamp, Corien D M and Bos, Foskea P and Sluis, Corry K van der and Broek, Marieke van den and Onneweer, Bram and Stolwijk-Swüste, Janneke M and Brink, Sander M and Voet, Nicoline B M and Rietman, Johan S and Prange-Lasonder, Gerdienke B},
  title = {Therapy effect on hand function after home use of a wearable assistive soft-robotic glove supporting grip strength},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0306713}
}
Kostenlos starten →