Multichannel ballistocardiography: A comparative analysis of heartbeat detection across different body locations
PLOS ONE · 01.08.2024 · 19 (8) · e0306074
DOI: 10.1371/journal.pone.0306074 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift PLOS ONE, online erschienen am 01.08.2024. Verfasst von Martina Ladrova und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, Os…. Hauptthemen laut MEDLINE: Ballistocardiography, Heart Rate, Electrocardiography. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Education of the Czechia, European Union under the REFRESH - Research Excellence For REgion Sustainability and High-tech Industries.
Abstract (Originalsprache)
The paper presents a validation of novel multichannel ballistocardiography (BCG) measuring system, enabling heartbeat detection from information about movements during myocardial contraction and dilatation of arteries due to blood expulsion. The proposed methology includes novel sensory system and signal processing procedure based on Wavelet transform and Hilbert transform. Because there are no existing recommendations for BCG sensor placement, the study focuses on investigation of BCG signal quality measured from eight different locations within the subject’s body. The analysis of BCG signals is primarily based on heart rate (HR) calculation, for which a J-wave detection based on decision-making processes was used. Evaluation of the proposed system was made by comparing with electrocardiography (ECG) as a gold standard, when the averaged signal from all sensors reached HR detection sensitivity higher than 95% and two sensors showed a significant difference from ECG measurement.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB-Technical University of Ostrava, Ostrava, Czechia.
ORCID-Profile: Jindrich Brablik, Rene Jaros, Radek Martinek
Förderung
- Ministry of Education of the Czechia
- European Union under the REFRESH - Research Excellence For REgion Sustainability and High-tech Industries
Zitieren
APA
Ladrova, M., Barvik, F., Brablik, J., Jaros, R., & Martinek, R. (2024). Multichannel ballistocardiography: A comparative analysis of heartbeat detection across different body locations. PLOS ONE, 19(8), e0306074. https://doi.org/10.1371/journal.pone.0306074
Vancouver
Ladrova M, Barvik F, Brablik J, Jaros R, Martinek R. Multichannel ballistocardiography: A comparative analysis of heartbeat detection across different body locations. PLOS ONE. 2024;19(8):e0306074. doi:10.1371/journal.pone.0306074
BibTeX
@article{Ladrova2024,
author = {Ladrova, Martina and Barvik, Filip and Brablik, Jindrich and Jaros, Rene and Martinek, Radek},
title = {Multichannel ballistocardiography: A comparative analysis of heartbeat detection across different body locations},
journal = {PLOS ONE},
year = {2024},
volume = {19},
number = {8},
pages = {e0306074},
doi = {10.1371/journal.pone.0306074}
}
EUVIMED