Intrastromal graft of anterior lens capsule. A substitute for Bowman layer graft transplantation for keratoconus
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0306015 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Carlos A Rodríguez-Barrientos und 5 weiteren Autor:innen. Beteiligte Einrichtung: Escuela Superior de Oftalmologia, Instituto Barraquer de America, Bogota, Colombia. Hauptthemen laut MEDLINE: Keratoconus, Corneal Transplantation, Corneal Stroma. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
The shortage of donor corneas limits Bowman layer transplantation for keratoconus. In this study, we evaluate the clinical outcome of porcine anterior lens capsule (xenograft) transplantation in the corneal stroma of a rabbit model as substitute for Bowman layer graft that is used in stromal transplantation for advanced keratoconus.
Methods
Transplantation of porcine anterior lens capsule in the corneal stroma was performed in four New Zealand white rabbits through the creation of a stromal pocket. Corneal transparency, central corneal thickness, and topographic characteristics of corneas were evaluated at different time points: pre- (0) and post- (7, 14, 21, and 28) operative days. Additionally, at the end of the study histopathological findings were evaluated.
Results
In comparison to pre-operative day, transplantation of an anterior lens capsule preserved corneal transparency, central corneal thickness, and topographic characteristics remained constant throughout the study period. Histopathological analysis revealed the presence of the anterior lens capsule as a fully integrated lamellar graft without adverse effects in host stroma.
Conclusion
The anterior lens capsule may be useful as a graft for intrastromal corneal trasplantation. Similarly to Bowman layer, anterior lens capsule has mechanical characteristics that facilitate corneal transplantation. In post-transplanted corneas the preservation of transparency, as well as the effect on corneal thickness, and topographic characteristics support the possibility of using anterior lens capsule as a substitute for Bowman layer graft.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Escuela Superior de Oftalmologia, Instituto Barraquer de America, Bogota, Colombia.
- Escuela de Medicina y Ciencias de la Salud, Tecnologico de Monterrey, Monterrey, Mexico.
ORCID-Profile: Carlos A Rodríguez-Barrientos, Amir Translateur-Grynspan
Zitieren
APA
Rodríguez-Barrientos, C. A., Translateur-Grynspan, A., Zavala, J., Valdez, J. E., Santaella, G., & Barraquer-Coll, C. (2024). Intrastromal graft of anterior lens capsule. A substitute for Bowman layer graft transplantation for keratoconus. PLOS ONE. https://doi.org/10.1371/journal.pone.0306015
Vancouver
Rodríguez-Barrientos CA, Translateur-Grynspan A, Zavala J, Valdez JE, Santaella G, Barraquer-Coll C. Intrastromal graft of anterior lens capsule. A substitute for Bowman layer graft transplantation for keratoconus. PLOS ONE. 2024. doi:10.1371/journal.pone.0306015
BibTeX
@article{RodrguezBarrientos2024,
author = {Rodríguez-Barrientos, Carlos A and Translateur-Grynspan, Amir and Zavala, Judith and Valdez, Jorge E and Santaella, Gisella and Barraquer-Coll, Carmen},
title = {Intrastromal graft of anterior lens capsule. A substitute for Bowman layer graft transplantation for keratoconus},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0306015}
}
EUVIMED