Phantomless calibration of CT scans for hip fracture risk prediction in silico: Comparison with phantom-based calibration

Julia A Szyszko iD, Alessandra Aldieri, Antonino A La Mattina iD, Marco Viceconti iD

PLOS ONE · 2024

DOI: 10.1371/journal.pone.0305474 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift PLOS ONE, 2024. Verfasst von Julia A Szyszko und 3 weiteren Autor:innen. Beteiligte Einrichtung: Medical Technology Lab, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Phantoms, Imaging, Hip Fractures. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Horizon 2020 Framework Programme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Finite element models built from quantitative computed tomography images rely on element-wise mapping of material properties starting from Hounsfield Units (HU), which can be converted into mineral densities upon calibration. While calibration is preferably carried out by scanning a phantom with known-density components, conducting phantom-based calibration may not always be possible. In such cases, a phantomless procedure, where the scanned subject’s tissues are used as a phantom, is an interesting alternative. The aim of this study was to compare a phantom-based and a phantomless calibration method on 41 postmenopausal women. The proposed phantomless calibration utilized air, adipose, and muscle tissues, with reference equivalent mineral density values of -797, -95, and 38 mg/cm 3 , extracted from a previously performed phantom-based calibration. A 9-slice volume of interest (VOI) centred between the femoral head and knee rotation centres was chosen. Reference HU values for air, adipose, and muscle tissues were extracted by identifying HU distribution peaks within the VOI, and patient-specific calibration was performed using linear regression. Comparison of FE models calibrated with the two methods showed average relative differences of 1.99% for Young’s modulus1.30% for tensile and 1.34% for compressive principal strains. Excellent correlations (R 2 > 0.99) were identified for superficial maximum tensile and minimum compressive strains. Maximum normalised root mean square relative error (RMSRE) values settled at 4.02% for Young’s modulus, 2.99% for tensile, and 3.22% for compressive principal strains, respectively. The good agreement found between the two methods supports the adoption of the proposed methodology when phantomless calibration is needed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedPhantoms, ImagingHip FracturesHumansCalibrationFemaleAgedBone DensityFinite Element AnalysisComputer SimulationMiddle AgedAged, 80 and over

Autor:innen und Institutionen

  • Medical Technology Lab, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.
  • Department of Industrial Engineering, Alma Mater Studiorum-University of Bologna, Bologna, Italy.
  • PolitoBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Torino, Italy.

ORCID-Profile: Julia A Szyszko, Antonino A La Mattina, Marco Viceconti

Förderung

  • Horizon 2020 Framework Programme

Zitieren

APA

Szyszko, J. A., Aldieri, A., La Mattina, A. A., & Viceconti, M. (2024). Phantomless calibration of CT scans for hip fracture risk prediction in silico: Comparison with phantom-based calibration. PLOS ONE. https://doi.org/10.1371/journal.pone.0305474

Vancouver

Szyszko JA, Aldieri A, La Mattina AA, Viceconti M. Phantomless calibration of CT scans for hip fracture risk prediction in silico: Comparison with phantom-based calibration. PLOS ONE. 2024. doi:10.1371/journal.pone.0305474

BibTeX
@article{Szyszko2024,
  author = {Szyszko, Julia A and Aldieri, Alessandra and La Mattina, Antonino A and Viceconti, Marco},
  title = {Phantomless calibration of CT scans for hip fracture risk prediction in silico: Comparison with phantom-based calibration},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0305474}
}
Kostenlos starten →