Effects of precise cardio sounds on the success rate of phonocardiography
PLOS ONE · 2024
DOI: 10.1371/journal.pone.0305404 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Youngsin Kim und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang, Gyeongbuk, Republic of Korea. Hauptthemen laut MEDLINE: Heart Sounds, Neural Networks, Computer. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Trade, Industry and Energy, Seoul St. Mary’s Hospital, Catholic University of Korea.
Abstract (Originalsprache)
This work investigates whether inclusion of the low-frequency components of heart sounds can increase the accuracy, sensitivity and specificity of diagnosis of cardiovascular disorders. We standardized the measurement method to minimize changes in signal characteristics. We used the Continuous Wavelet Transform to analyze changing frequency characteristics over time and to allocate frequencies appropriately between the low-frequency and audible frequency bands. We used a Convolutional Neural Network (CNN) and deep-learning (DL) for image classification, and a CNN equipped with long short-term memory to enable sequential feature extraction. The accuracy of the learning model was validated using the PhysioNet 2016 CinC dataset, then we used our collected dataset to show that incorporating low-frequency components in the dataset increased the DL model’s accuracy by 2% and sensitivity by 4%. Furthermore, the LSTM layer was 0.8% more accurate than the dense layer.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Mechanical Engineering, Pohang University of Science and Technology, Pohang, Gyeongbuk, Republic of Korea.
- Department of Thoracic and Cardiovascular Surgery, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
ORCID-Profile: Wonkyu Moon
Förderung
- Ministry of Trade, Industry and Energy
- Seoul St. Mary’s Hospital, Catholic University of Korea
Zitieren
APA
Kim, Y., Moon, M., Moon, S., & Moon, W. (2024). Effects of precise cardio sounds on the success rate of phonocardiography. PLOS ONE. https://doi.org/10.1371/journal.pone.0305404
Vancouver
Kim Y, Moon M, Moon S, Moon W. Effects of precise cardio sounds on the success rate of phonocardiography. PLOS ONE. 2024. doi:10.1371/journal.pone.0305404
BibTeX
@article{Kim2024,
author = {Kim, Youngsin and Moon, Mihyung and Moon, Seokwhwan and Moon, Wonkyu},
title = {Effects of precise cardio sounds on the success rate of phonocardiography},
journal = {PLOS ONE},
year = {2024},
doi = {10.1371/journal.pone.0305404}
}
EUVIMED