EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

In vitro experimental conditions and tools can influence the safety and biocompatibility results of antimicrobial electrospun biomaterials for wound healing

In-vitro-Experimentbedingungen und Werkzeuge können die Sicherheits- und Biokompatibilitätsergebnisse antimikrobieller elektrogesponnener Biomaterialien für die Wundheilung beeinflussen

Kaisa Põhako-Palu, Kairi Lorenz, Kelli Randmäe, Marta Putrinš, Külli Kingo, Tanel Tenson, Karin Kogermann iD

PLOS ONE · 01.07.2024 · 19 (7) · e0305137

DOI: 10.1371/journal.pone.0305137 ↗

Auf einen Blick

Die Studie verglich In-vitro-Zytotoxizitätsassays für elektrogesponnene Wundauflagen. Die Ergebnisse hingen deutlich vom Versuchsaufbau ab; Direktkontakt-Assays zeigten die Biokompatibilität am besten.

Fragestellung

Es sollte ein geeigneter und biorelevanter In-vitro-Zytotoxizitätsassay für elektrogesponnene Biomaterialien entwickelt werden.

Methode

Vergleich verschiedener In-vitro-Zytotoxizitätsassays mit einem Modell-Wundverband aus Polycaprolacton, Polyethylenoxid und Chloramphenicol; getestet wurden Auslaugung und Direktkontakt mit BHK-21, humanen Fibroblasten, MTS und Echtzeit-Zellanalyse.

Ergebnisse

Die Auslaugungsassays eigneten sich für das erste Screening. In Direktkontakt-Assays wurde die Biokompatibilität sichtbar. Zelllinie, Medium, Kontrollen und ein Phosphatpuffer-Waschschritt beeinflussten das Ergebnis signifikant.

Schlussfolgerung der Autor:innen

Die Autor:innen entwickelten ein detaillierteres technisches Protokoll für die In-vitro-Zytotoxizitätsbewertung elektrogesponnener Wundauflagen.

Kernaussagen

  • Auslaugungsassays sind für das initiale Testing geeignet
  • Direktkontakt-Assays zeigen die Biokompatibilität besser
  • Versuchsaufbau und Kontrollen beeinflussen das Ergebnis deutlich

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 01.07.2024. Verfasst von Kaisa Põhako-Palu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Pharmacy, University of Tartu, Tartu, Estonia. Hauptthemen laut MEDLINE: Wound Healing, Biocompatible Materials, Bandages. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Eesti Teadusagentuur.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrospun (ES) fibrous nanomaterials have been widely investigated as novel biomaterials. These biomaterials have to be safe and biocompatible; hence, they need to be tested for cytotoxicity before being administered to patients. The aim of this study was to develop a suitable and biorelevant in vitro cytotoxicity assay for ES biomaterials (e.g. wound dressings). We compared different in vitro cytotoxicity assays, and our model wound dressing was made from polycaprolactone and polyethylene oxide and contained chloramphenicol as the active pharmaceutical ingredient. Baby Hamster Kidney cells (BHK-21), human primary fibroblasts and MTS assays together with real-time cell analysis were selected. The extract exposure and direct contact safety evaluation setups were tested together with microscopic techniques. We found that while extract exposure assays are suitable for the initial testing, the biocompatibility of the biomaterial is revealed in in vitro direct contact assays where cell interactions with the ES wound dressing are evaluated. We observed significant differences in the experimental outcome, caused by the experimental set up modification such as cell line choice, cell medium and controls used, conducting the phosphate buffer washing step or not. A more detailed technical protocol for the in vitro cytotoxicity assessment of ES wound dressings was developed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wound HealingBiocompatible MaterialsBandagesAnimalsHumansCell LineMaterials TestingCricetinaePolyestersFibroblastsAnti-Infective AgentsPolyethylene GlycolsChloramphenicol

Substanzen

Biocompatible MaterialsPolyesterspolycaprolactoneAnti-Infective AgentsPolyethylene GlycolsChloramphenicol

Autor:innen und Institutionen

  • Institute of Pharmacy, University of Tartu, Tartu, Estonia.
  • Dermatology Clinic, Tartu University Hospital, Tartu, Estonia.
  • Institute of Clinical Medicine, University of Tartu, Tartu, Estonia.
  • Institute of Technology, University of Tartu, Tartu, Estonia.

ORCID-Profile: Karin Kogermann

Förderung

  • Eesti Teadusagentuur

Zitieren

APA

Põhako-Palu, K., Lorenz, K., Randmäe, K., Putrinš, M., Kingo, K., Tenson, T., & Kogermann, K. (2024). In vitro experimental conditions and tools can influence the safety and biocompatibility results of antimicrobial electrospun biomaterials for wound healing. PLOS ONE, 19(7), e0305137. https://doi.org/10.1371/journal.pone.0305137

Vancouver

Põhako-Palu K, Lorenz K, Randmäe K, Putrinš M, Kingo K, Tenson T, et al. In vitro experimental conditions and tools can influence the safety and biocompatibility results of antimicrobial electrospun biomaterials for wound healing. PLOS ONE. 2024;19(7):e0305137. doi:10.1371/journal.pone.0305137

BibTeX
@article{PhakoPalu2024,
  author = {Põhako-Palu, Kaisa and Lorenz, Kairi and Randmäe, Kelli and Putrinš, Marta and Kingo, Külli and Tenson, Tanel and Kogermann, Karin},
  title = {In vitro experimental conditions and tools can influence the safety and biocompatibility results of antimicrobial electrospun biomaterials for wound healing},
  journal = {PLOS ONE},
  year = {2024},
  volume = {19},
  number = {7},
  pages = {e0305137},
  doi = {10.1371/journal.pone.0305137}
}
Kostenlos starten →