EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Axial compression behavior of carbon fiber reinforced polymer confined partially encased recycled concrete columns

Yunchen Wang, Jiongfeng Liang, Caisen Wang, Wei Li iD

PLOS ONE · 2024

DOI: 10.1371/journal.pone.0304797 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PLOS ONE, 2024. Verfasst von Yunchen Wang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Civil & Architecture Engineering, East China University of Technology, Nanchang, China. Hauptthemen laut MEDLINE: Carbon Fiber, Construction Materials, Recycling, Polymers. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Project of academic and technological leaders of major disciplines in Jiangxi Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Partially encased concrete (PEC) has better mechanical properties as a structure where steel and concrete work together. Due to the increasing amount of construction waste, recycled aggregate concrete (RAC) is being considered by more people. However, although RAC has more points, the performance is inferior to natural aggregate concrete (NAC). To narrow or address this gap, lightweight, high-strength and corrosion-resistant CFRP can be used, also protecting the steel flange of the PEC structure. Therefore, carbon fiber reinforced polymer (CFRP) confined partially encased recycled coarse aggregate concrete columns were studied in this paper. With respect to different slenderness ratios, recycled coarse aggregate(RCA) replacement ratios, and number of CFRP layers, the performance of the proposed CFRP restrained columns are reported. The RCA replacement ratio is analyzed to be limited negative impact on the bearing capacity, generally within 6%. As for the slenderness ratio, the bearing capacity increased with it. However, wrapping CFRP significantly increased the bearing capacity. Considering the arch factor, a simple formula for calculating the ultimate strength of CFRP-confined partially encased RAC columns is developed based on EC4 and GB50017-2017. By comparison with the experimental values, the error is within 10%.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carbon FiberConstruction MaterialsRecyclingPolymersCompressive StrengthMaterials TestingSteel

Substanzen

Carbon FiberPolymersSteel

Autor:innen und Institutionen

  • Faculty of Civil & Architecture Engineering, East China University of Technology, Nanchang, China.
  • Faculty of Architecture, Civil and Transportation Engineering, Beijing University of Technology, Beijing, China.
  • College of Civil and Architecture Engineering, Wenzhou University, Wenzhou, China.
  • Key Laboratory of Engineering and Technology for Soft Soil Foundation and Tideland Reclamation of Zhejiang Province, Wenzhou, China.

ORCID-Profile: Wei Li

Förderung

  • National Natural Science Foundation of China
  • Project of academic and technological leaders of major disciplines in Jiangxi Province

Zitieren

APA

Wang, Y., Liang, J., Wang, C., & Li, W. (2024). Axial compression behavior of carbon fiber reinforced polymer confined partially encased recycled concrete columns. PLOS ONE. https://doi.org/10.1371/journal.pone.0304797

Vancouver

Wang Y, Liang J, Wang C, Li W. Axial compression behavior of carbon fiber reinforced polymer confined partially encased recycled concrete columns. PLOS ONE. 2024. doi:10.1371/journal.pone.0304797

BibTeX
@article{Wang2024,
  author = {Wang, Yunchen and Liang, Jiongfeng and Wang, Caisen and Li, Wei},
  title = {Axial compression behavior of carbon fiber reinforced polymer confined partially encased recycled concrete columns},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0304797}
}